American Lithium Corp.TSXV: LI

American Lithium 162 Assays for Near Surface Brine Samples and Sonic Core Samples, North Playa Fish Lake Valley

· Issued by American Lithium Corp. via GlobeNewswire

VANCOUVER, BRITISH COLUMBIA--(Marketwired - April 18, 2017) - American Lithium Corp. (TSX VENTURE:LI)(OTCQB:LIACF)(FRANKFURT:5LA)(WKN:A2AHEL) ("American Lithium"; or, the "Company") is pleased to announce brine sample assay results from near surface auger sampling and brine and sediment samples for shallow sonic drilling on the North Playa, Fish Lake Valley, Esmeralda County, Nevada.

Results from the final 162 near surface brine samples are presented below. Results from the ALS assays of the complete sample set range from trace to 300 mg/l, (see Table 3 at the end of the press release). The lowest concentrations encountered lie along the Southeastern bounds of the sampling area and are interpreted to represent a delineation in structural compartments following structural trends in Fish Lake Valley. The highest grouping of assay values, 55 samples from the center of the North Playa, contains concentrations averaging 160 mg/L and a range of 100 ml/L to 300 mg/L. These results are congruent with the expectation that the lithium brines should have the highest concentrations in the playa center (see sample map below).

To view Figure 1 - All Brine sample location (old and new) and grade range, drill hole locations as stars, please visit the following link: http://media3.marketwire.com/docs/Figure1_1091946.jpg

"Highs of 300mg/L Li in near surface brine samples and 452 ppm Li in near surface sediments validate the North Playa as a strong exploration target for economic lithium resources," comments Interim CEO Michael Kobler. "American Lithium looks forward to drill in the North Playa in 2017as soon as surface conditions permit."

Sediment samples collected from the 2016 sonic drilling intersected high near-collar concentrations; BH13B showing an average grade of water soluble Lithium of 276 ppm Li over the upper 10' (including 5' of 452 ppm Li from 0-5' and 5' of 101.5 ppm Li from 5-10'), and L16-24 averaging 101 ppm Li, (including 5' of 153.5 ppm Li from 0-5' and 5' of 48.9 ppm Li from 5-10'). Additional investigation of sediments is planned for future exploration programs.

Table #1, Sonic drill hole, downhole sediment samples

Sample IDHole IDDepth
From-To
(ft)
Li
(ppm)
Sample IDHole
ID
Depth
From-To
(ft)
Li
(ppm)
143094913B0-54521430953240-5153.5
143095013B5-10101.51430954245-1049.8
143095113B10-1522.814309552410-158.15
143095213B15-2010.514309562415-205.66

Early conceptual modeling (Garrett, DE) and investigation by Oldow suggest deep brine aquifers are structurally controlled and conductivity to the shallow aquifer is facilitated by structural conduits. Discrete hydrosleeve samples were collected at regular intervals from 37 feet to completed depth of the 2016 sonic boreholes. Samples were re-assayed following the inconsistent laboratory observed from the Shallow Sampling Program. Results indicate that the aquifers intersected in these locations are not directly linked to the structures responsible for lithium transport to the near surface aquifer. However, the increase in sodium near the cutoff depth of Hole # 13A is a strong vector for deeper brine enrichment and requires a deeper drilling program.

Table #2 Down hole Hydrosleeve samples

HoleSample
Number
Depth
(ft)
Li
(mg/L)
Na
(mg/L)
HoleSample
number
Depth
(ft)
Li
(mg/L)
Na (mg/L)
N-16-5143090137<1020013A143091841310900
N-16-51430902123<1010013A143091945710900
N-16-51430903161<1010013A143092045710900
N-16-51430904195<1010013A1430922497104500
N-16-514309052451010024143092743<10800
N-16-51430906297<1010024143092987<10600
N-16-5143090733810100241430931127<10200
N-16-51430908368<10100241430933177<10300
13A143090937101100241430935237<10300
13A143091083101300241430937277<10200
13A1430911127101100241430939318<10200
13A1430913213101100241430940318<10200
13A1430914257101000241430941358<10200
13A143091529710900241430943408<10200
13A143091633710900241430945448<10200
13A143091737710900241430947498<10200

Future drilling and sampling are planned to test the conceptual model, enhance understanding of the controls to Fish Lake Valley's brine hosted lithium, as well as a more comprehensive investigation of lithium bearing sediments and their economic potential.

Near surface brine samples for the first 25 samples were collected by using a conventional hand held auger to sample sub surface brines at a depth of 78" (2m), The brine was sampled at the bottom of the auger hole and then separated from residual clays before being sent for analysis. For the subsequent near surface brine sampling program the Company developed a new methodology for sampling. Instead of an auger system, a four-inch diameter pipe is driven into the ground to a depth of approximately 55" (1.4m) and then pulled out of the hole. A 2.5" (6.3cm) perforated pvc pipe is placed in the hole to keep it open while clay solids settle to the bottom of the hole. The brine is then sampled just above the settled material at the bottom of the hole. The change in sampling method was driven by the difficulty of operating an auger in wet playa clays. Both processes return a similar near surface brine sample.

Hydrosleeve samples were gather by dropping a closed plastic sleeve down through the collar of the Sonic drill barrel into the open hole below. When the sleeve reached the target depth, it was pulled back up. The upward motion opened the check valve at the mouth of the sleeve which filled with liquid from that depth of the hole. Once it is filled the check valve closes and seals the sample. On surface the sample was poured out into a container to decant some of the suspended solids and then placed in a sample bottle to be sent to the assay laboratory.

Sonic borings were continually logged at the drill rig by the site geologist to classify sediments and identify stratigraphy. Down hole sediment samples were taken as splits from soft sediments retrieved in the sonic drilling process a representative portion was saved from reference.

The QP requested blank material (tap water or barren clays) to be inserted on a 5% basis as were duplicate samples. This protocol was not implemented by the site geologist and this error was not discovered until the end of the short program. It is not expected that either of these two actions would have identified the flawed assays any earlier than was done. Neither the Company nor the QP are aware of Lithium standard material for brines that would have been available for insertion into the samples stream at the time of the program. Insertion of independent standard material would have revealed the assay problems earlier in the process. The absence of certified standards is not unreasonable in an early stage exploration program. The Company is currently working on obtaining relevant certified lithium standard materials for future programs.

Two samples were collected in the field at each location by independent third party contractors, both were clearly labeled, stored in a secure climate controlled facility and then one was shipped by courier to Reno, Nevada where the samples were submitted to either Florin or subsequently to ALS facilities. Excepting the previously discussed "flawed assays," the reported assays in this press release were processed at the ALS Minerals Laboratory in Reno Nevada and analyzed at the ALS facility in Vancouver BC. The lithium brine samples were collected, diluted and analyzed directly by inductively coupled plasma - atomic emission spectrometry (ICP-AES). Down hole sediment samples were dissolved with a de-ionized water leach, and analyzed directly by inductively coupled plasma - atomic emission spectrometry (ICP-AES).

Michael Collins, P.Geo. is the Company's designated Qualified Person within the meaning of National Instrument 43-101, he is independent of the company, and has reviewed and approved the technical information contained in this news release.

Table #4 All near surface brine sample results

Sample IDRevised
assays
Li (mg/L)
Sample IDRevised
assays
Li (mg/L)
Sample IDRevised
assays
Li (mg/L)
Sample IDRevised
assays
Li (mg/L)
Sample IDRevised
assays
Li (mg/L)
1431001*NSS1431044*1001431089401431133901431179100
1431002*701431045*901431090601431134901431180110
1431003*NSS1431046*801431091<101431135401431181100
1431004*1101431047*8014310921014311361101431182100
1431005*1201431048*601431093<1014311371001431183100
1431006*901431049*5014310942014311381201431184100
1431007*1001431050*5014310951014311391001431185100
1431008*601431051*110143109610143114080143118690
1431009*901431052*1001431097401431141801431187100
1431010*101431053*9014310984014311421101431188100
1431011*901431054*1301431099<101431143110143118990
1431012*40143105511014311001014311441301431190100
1431013*901431056160143110115014311451101431191110
1431014*1201431057100143110221014311461401431192100
1431015*9014310589014311031401431147601431193110
1431016*100143105911014311051901431148801431194120
1431017*2014310609014311061301431149801431195140
1431018*10143106112014311079014311501401431196180
1431019*10143106290143110814014311511201431197240
1431020*NSS143106330143110911014311521301431198260
1431021*<10143106490143111011014311531501431199200
1431022*<101431065110143111112014311541801431200150
1431023*20143106630143111213014311552301431201150
1431024*401431067110143111316014311561901431202130
1431025*20143106890143111425014311571801431203140
1431026*60143106960143111521014311581201431204110
1431027*9014310701501431116140143115990143120590
1431028*70143107170143111710014311631101431206120
1431029*7014310729014311189014311641001431207120
1431030*80143107370143111910014311651101431208300
1431031*70143107410014311209014311661101431209290
1431032*70143107512014311213014311671201431210180
1431033*4014310769014311226014311681401431211150
1431034*1014310779014311237014311691301431212150
1431035*30143107810014311247014311701101431213160
1431036*60143107910014311258014311711201431214190
1431037*701431080100143112611014311721201431215200
1431038*701431081120143112710014311731301431216220
1431039*801431082110143112810014311741101431217210
1431040*901431083100143112910014311751301431218180
1431041*9014310849014311309014311761201431219160
1431042*10014310856014311318014311771601431220140
1431043*901431086801431132901431178120
* denotes samples that were previously reported, NNS denotes non-sufficient sample

For more information, please visit our website at www.americanlithiumcorp.com.

ABOUT American Lithium Corp.

American Lithium Corp. is actively engaged in the acquisition, exploration and development of lithium deposits within mining-friendly jurisdictions throughout the Americas. American Lithium holds options to acquire Nevada lithium brine claims totaling 22,332 acres (9,038 ha), including 18,552 contiguous acres (7,508 ha) in Fish Lake Valley, Esmeralda County; 2,240 acre (907 ha) San Emidio Project in Washoe County; and the 1,540 acre (623 ha) Clayton-Valley-1 Project. The Company's Fish Lake Valley lithium brine properties are located approximately 38 kilometers from Albemarle's Silver Peak, the largest lithium operation in the U.S. American Lithium is listed on the TSXV under the trading symbol "Li". For further information, please visit the Company's website at www.americanlithiumcorp.com.

On behalf of the Board, American Lithium Corp.

Michael Kobler, Interim Chief Executive Officer

Neither TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of this release.

Contact Information:

American Lithium Corp.
Michael Kobler
Interim Chief Executive Officer
1-604-689-7422
[email protected]
www.americanlithiumcorp.com

View original source (GlobeNewswire)American Lithium Corp. on 6ix

Earlier from American Lithium

Later from American Lithium

All American Lithium news releases