Smith & Nephew plc · LSE:SN.

Smith & Nephew — 2008 American Academy of Orthopaedic Surgeons (AAOS) Annual Meeting

94 slides from Smith & Nephew's conference presentation, Mar 5, 2008

  1. Slide 1: 2008 American Academy of Orthopaedic Surgeons

    Slide 1: 2008 American Academy of Orthopaedic Surgeons

    2008 American Academy of Orthopaedic Surgeons Welcome to the Smith & Nephew analyst meeting March 5th 2008 1

  2. Slide 2: Forward looking statements

    Slide 2: Forward looking statements

    Forward looking statements This presentation contains certain "forward-looking statements" within the meaning of the US Private Securities Litigation Reform Act of 1995. In particular, statements regarding expected revenue growth and trading margins discussed under "Outlook" are forward- looking sta

  3. Slide 3: Continuum of care

    Slide 3: Continuum of care

    Continuum of care Being part of the orthopaedic surgeon’s daily life 3

  4. Slide 4: Repair, rebuild....restore

    Slide 4: Repair, rebuild....restore

    Repair, rebuild....restore We give you advanced products for a continuum of patient care

  5. Slide 5: Strategy for continued value growth

    Slide 5: Strategy for continued value growth

    Strategy for continued value growth • Customer and market focus – Innovation to provide clinical benefits and value for healthcare systems – Focus on active informed patients • Value enhancing acquisitions – Unique/additive technologies – Improved channels to market • Earnings improvement – Aim for

  6. Slide 6: Endoscopy

    Slide 6: Endoscopy

    Endoscopy Mike Frazzette President

  7. Slide 7: Improving Lives through Innovative Arthroscopy

    Slide 7: Improving Lives through Innovative Arthroscopy

    Vision Improving Lives through Innovative Arthroscopy

  8. Slide 8: Continuum of care

    Slide 8: Continuum of care

    Continuum of care Being part of the orthopedic surgeon's daily life be smith&nephew | Skiing sport injury RESTORE Disease Treatment options Product ACL Rupture with Meniscal Suture a ULTRA FAST-FIX° meniscal tear BS Meniscal Repair System a Arthroscopic ACL Repair a ACUFEX 5 Anatomic ACL Guide Syste

  9. Slide 9: 2007 – portfolio innovation

    Slide 9: 2007 – portfolio innovation

    2007 – portfolio innovation KNEE KNEE HIP ENDOBUTTON™ DIRECT CLANCY ANATOMIC Hip Lateral Positioning System Fixation Device CRUCIATE GUIDE Gently separates hip joint for optimal An ideal solution for accommodating shorter Flexible Drill System access to repair site; femoral tunnels For both single a

  10. Slide 10: 2007 – portfolio innovation

    Slide 10: 2007 – portfolio innovation

    2007 – portfolio innovation SHOULDER VISUALIZATION ACCESS KINSA™ RC 5.5 560 HD Camera System CLEAR-TRAC™ COMPLETE and Rotator Cuff Suture Anchor End-to-end professional broadcast FLEXIBLE Cannula Systems For any type of cuff tear, the result is a quality High Definition for your OR Suture management

  11. Slide 11: Smith & Nephew highlights for AAOS 2008

    Slide 11: Smith & Nephew highlights for AAOS 2008

    Smith & Nephew highlights for AAOS 2008 Booth # 4246 11

  12. Slide 12: Key capital products at AAOS

    Slide 12: Key capital products at AAOS

    Key capital products at AAOS HIP VISUALIZATION DYONICS™ D2 Lateral Hip Distractor HD Video Platform Next Gen Power Source Greatest range of motion True HD 3CCD Head -Beta testing available for accessing hip joint True HD Video Processor HD VideoArthroscopes -Early stages Simple design, easy to use,

  13. Slide 13: Key Sports Medicine/Repair products at AAOS

    Slide 13: Key Sports Medicine/Repair products at AAOS

    Key Sports Medicine/Repair products at AAOS KNEE SHOULDER ACUFEX™ ANATOMIC ACL Guide System TWINFIX FOOTPRINT PK Suture Anchor ULTRA FAST-FIX™ Meniscal Repair System KINSA™ RC 5.5 Rotator Cuff Suture Anchor ENDOBUTTON™ CL ULTRA Fixation Device BIORAPTOR™ 2.3 PK Suture Anchor TRUREPAIR™ CLEAR-TRAC™ C

  14. Slide 14: Company-to-surgeon connection

    Slide 14: Company-to-surgeon connection

    Company-to-surgeon connection INVENTURES Partnership for Rapid Product Development – connecting inventing surgeons with market-leading sports medicine company Surgeon idea/concept submission pathway – from paper to prototype A total business partnership Prototyping, evaluation and testing Commercial

  15. Slide 15: Surgeon-to-surgeon connections

    Slide 15: Surgeon-to-surgeon connections

    Surgeon-to-surgeon connections Anatomic Single-Double Bundle New Approaches in Shoulder Hamstring ACL Recon Arthroscopy Charlie Brown, MD James Andrews, MD Improvements in Access for Innovations in Rotator Cuff Repair using Arthroscopic Hip Repair the FOOTPRINT PK Suture Anchor Victor Ilizaliturri,

  16. Slide 16: 2008 focus

    Slide 16: 2008 focus

    2008 focus Talent Drive “Customer Intensity” culture Invest in the key revenue drivers to help maintain and grow our market leadership position Drive Innovation -- focused organic growth effort with a robust business development plan Invest in Surgeon and Sales force education Operational Excellence

  17. Slide 17: Shoulder Arthroscopy: The State of the Science

    Slide 17: Shoulder Arthroscopy: The State of the Science

    Shoulder Arthroscopy: The State of the Science Nikhil N. Verma, MD Assistant Professor Orthopedic Surgery Rush University Medical Center Midwest Orthopedics at Rush

  18. Slide 18: Education

    Slide 18: Education

    Education „ University of Pennsylvania School of Medicine „ Rush University Orthopedic Residency Program „ Fellowship: Hospital for Special Surgery Sports and Shoulder Service

  19. Slide 19: Practice Profile

    Slide 19: Practice Profile

    Practice Profile „ Sports Medicine: Knee, Shoulder, Elbow „ Academic Practice „ Fellowship „ Residency „ 450 procedures/year „ 70% Arthroscopic

  20. Slide 20: Shoulder Arthroscopy and Rotator Cuff Repair

    Slide 20: Shoulder Arthroscopy and Rotator Cuff Repair

    Shoulder Arthroscopy and Rotator Cuff Repair „ Where have we been? „ Where are we now? „ Where are we going?

  21. Slide 21: “Scope” of the Problem

    Slide 21: “Scope” of the Problem

    “Scope” of the Problem* 2004 2005 2006 % Change Knee 1,598,018 1,642,190 1,698,056 +6.2% Arthroscopy Shoulder 723,308 804,097 873,802 +20.8% Arthroscopy Open 261,835 237,586 215,349 -17.7% Shoulder Solucient Inpatient & * US procedure data Outpatient procedure data, Thomson Healthcare

  22. Slide 22: Where have we been?

    Slide 22: Where have we been?

    Where have we been? „ Traditional Open Surgery „ Instability „ Rotator Cuff Repair/SubAcromial Decompression/Distal Clavicle Excision „ Arthroplasty

  23. Slide 23: Where have we been?

    Slide 23: Where have we been?

    Where have we been? „ It works!!! „ But….. „ Increased pain „ Collateral damage „ Increased Complications „ Patient Preference

  24. Slide 24: Shoulder Arthroscopy

    Slide 24: Shoulder Arthroscopy

    Shoulder Arthroscopy „ First described in 1930’s but popularized in 1980’s „ Enhanced Diagnostic view of the shoulder „ SLAP Lesion „ Andrews, 1985 „ Advantages „ Decreased morbidity „ Identification of concomitant pathology „ Patient Preference

  25. Slide 25: Shoulder Arthroscopy: Progression

    Slide 25: Shoulder Arthroscopy: Progression

    Shoulder Arthroscopy: Progression „ Development of Suture Anchor „ 1986 „ Allows development of arthroscopic repair techniques „ Bioabsorbable Material „ Radiolucent „ Reconstitution of bone „ Revisable

  26. Slide 26: Where are we now?

    Slide 26: Where are we now?

    Where are we now? „ Instability „ Rotator Cuff Repair / SubAcromial Decompression / Distal Clavicle Excision „ Arthroplasty

  27. Slide 27: Rotator Cuff Repair Results-Clinical

    Slide 27: Rotator Cuff Repair Results-Clinical

    Rotator Cuff Repair Results-Clinical „ Numerous studies demonstrating substantial improvement pain, function „ Gartsman „ Nottage „ Wolf „ Burkhart

  28. Slide 28: Results Clinical Cuff Integrity

    Slide 28: Results Clinical Cuff Integrity

    Results Clinical Cuff Integrity „ Pain „ Function „ Satisfaction ≠ „ Radiographic Study to Determine Cuff Healing

  29. Slide 29: Rotator Cuff Tears: Healing Rates

    Slide 29: Rotator Cuff Tears: Healing Rates

    Rotator Cuff Tears: Healing Rates „ Structural failure of RC repair most frequent complication „ Open and arthroscopic „ 13% to 90% at 6mos – 5 years post-op

  30. Slide 30: Post-Op Cuff Integrity

    Slide 30: Post-Op Cuff Integrity

    Post-Op Cuff Integrity „ Arthroscopic Techniques „ 30% of 1 and 2 tendon tears „ 60-90% of massive tears „ Results Appear Comparable to Open Techniques „ Tear Size „ Muscle Atrophy/Fatty Infiltration „ Host Factors (age, smoking)

  31. Slide 31: What’s the problem? Biology…

    Slide 31: What’s the problem? Biology…

    What’s the problem? Biology… Tendon Quality & Tendon to Bone healing…

  32. Slide 32: Mechanical & Biological

    Slide 32: Mechanical & Biological

    Mechanical B Biological „ Suture strength „ Prepare bone footprint „ Multiple Sutures „ Acromioplasty? „ Suture configuration Growth Factors ? „ Suture anchors Tendon to Bone Healing Double Row Fixation Maximize Contact Area Anatomic Repair Margin Convergence Interval Slides

  33. Slide 33: Mechanics of Repair Summary

    Slide 33: Mechanics of Repair Summary

    Mechanics of Repair Summary Single Row Double Row TOE „ 275N-300N „ 300-350 N „ 350-400 N „ No footprint „ Footprint (50-90%) „ Footprint (100%) „ Minimal „ Resistance to shear „ Gap formation “gap formation” „ Minimal “gap formation” „ Increased contact pressure

  34. Slide 34: Footprint Repair: Anchors

    Slide 34: Footprint Repair: Anchors

    Footprint Repair: Anchors „ TWINFIX™ FT (Fully Threaded) Suture Anchor „ Maximize pull out strength „ Single step insertion „ Less suture abrasion „ TWINFIX™ Footprint PK Suture Anchor „ Independent anchor insertion and suture tensioning „ Ease of insertion

  35. Slide 35: Footprint Repair: Technique

    Slide 35: Footprint Repair: Technique

    Footprint Repair: Technique

  36. Slide 36: Footprint Repair: Final Repair

    Slide 36: Footprint Repair: Final Repair

    Footprint Repair: Final Repair

  37. Slide 37: Surgeon Benefits

    Slide 37: Surgeon Benefits

    Surgeon Benefits „ Repair Standpoint „ Maximize repair strength „ Maximize contact area „ Maximize healing „ Technique Standpoint „ Fast „ Technically easy

  38. Slide 38: Patient Benefits

    Slide 38: Patient Benefits

    Patient Benefits „ Maximize Healing „ Maximize Functional Outcome „ Minimize Morbidity „ Patient Preference

  39. Slide 39: Double Row/TOE: Clinical Outcomes

    Slide 39: Double Row/TOE: Clinical Outcomes

    Double Row/TOE: Clinical Outcomes „ Clinical studies show high rates of healing „ Lafosse et al (JBJS, 2007) „ Huijsmans et al (JBJS, 2007) „ Sugaya et al (JBJS, 2007) „ Healed RC functioned better „ Healing rates of 83% to 89%

  40. Slide 40: Where are we going?

    Slide 40: Where are we going?

    Where are we going? „ Biology „ Chemical control of the healing cascade „ Biologic augmentation of bone or soft-tissue healing „ Five to Seven Years „ Remaining Issues „ Which factors? „ When? „ How do we get them there?

  41. Slide 41: Thank you!

    Slide 41: Thank you!

    Thank you!

  42. Slide 42: We are smith&nephew

    Slide 42: We are smith&nephew

    o/. 7.4 We are smith&nephew

  43. Slide 43: Orthopaedic Trauma & Clinical Therapies

    Slide 43: Orthopaedic Trauma & Clinical Therapies

    Orthopaedic Trauma & Clinical Therapies Mark Augusti, President

  44. Slide 44: sustainable profitable growth

    Slide 44: sustainable profitable growth

    sustainable profitable growth 18

  45. Slide 45: Trauma and Clinical Therapies Success

    Slide 45: Trauma and Clinical Therapies Success

    Trauma and Clinical Therapies Success Sustainable Societal, Health & Economic Factors Worldwide Markets • Aging population & active lifestyles • Higher incidence of OA • Increasing rates of osteoporosis Smith & Nephew’s Response • New products that will continue to drive growth • Strong investment i

  46. Slide 46: TRIGEN™ INTERTAN™ hip fracture device

    Slide 46: TRIGEN™ INTERTAN™ hip fracture device

    TRIGEN™ INTERTAN™ hip fracture device • Terrific successes and account conversions in US, Germany and Italy • Potential to get patients walking again sooner and reduce costs Innovative two-screw configuration secures nail in place after surgery and provides for greater stability and faster healing 2

  47. Slide 47: CAPTION™ Disposable Platelet Concentrator

    Slide 47: CAPTION™ Disposable Platelet Concentrator

    CAPTION™ Disposable Platelet Concentrator • Launched in January • Initial feedback has been very positive – Fully disposable – As much as 40% faster than centrifuge-based products with less contamination risk • Considerably more cost-efficient than BMP CAPTION™ concentrates platelets from patient’s

  48. Slide 48: PERI-LOC™ Locked Plating System

    Slide 48: PERI-LOC™ Locked Plating System

    PERI-LOC™ Locked Plating System • Significant growth in 2007 • Currently more than 20 plates in system for different anatomical locations • Upper Extremity system roll-out began in 2006 and continued throughout 2007 • European roll-out exceeding expectations • VLP system launched at end of 2007 and

  49. Slide 49: Please welcome Cory Collinge, MD

    Slide 49: Please welcome Cory Collinge, MD

    Please welcome Cory Collinge, MD Fellow of the American Academy of Orthopaedic Surgeons Orthopaedic Specialty Associates Harris Methodist Hospital Fort Worth, Fort Worth, TX PERI-LOC™ VLP Distal Tibia Plate 23

  50. Slide 50: PERI-LOC™ VLP

    Slide 50: PERI-LOC™ VLP

    PERI-LOC™ VLP Variable-Angle Locked Plating System Why is this important? Cory Collinge, MD Director of Orthopedic Trauma Harris Methodist Fort Worth Hospital John Peter Smith Orthopedic Residency Program Fort Worth, TX

  51. Slide 51: Some Fractures Not Optimally Treated

    Slide 51: Some Fractures Not Optimally Treated

    Some Fractures Not Optimally Treated AO/OTA Fracture Classification Type B ONLY Type A Fracture: • No fracture extension into the joint (i.e. completely extra-articular in the proximal tibia). Type B Fracture; • Partial articular fracture Type C Fracture: • Complete articular fracture

  52. Slide 52: Design Rationale – Clinical Perspective

    Slide 52: Design Rationale – Clinical Perspective

    Design Rationale – Clinical Perspective Axial Load Plate Fracture Treatment: • Types A and C see more stresses: – Need a stronger plate Fragment Movement Biomechanics: • Plate bears axial load

  53. Slide 53: Design Rationale – Clinical Perspective

    Slide 53: Design Rationale – Clinical Perspective

    Design Rationale – Clinical Perspective Axial Load Fracture Treatment: • Type B fractures: usually treated with a “buttress” plate Plate Biomechanics: Fragment Movement • Plate compresses bone into bone • Prevents failure by shearing

  54. Slide 54: Design Rationale – Clinical Perspective

    Slide 54: Design Rationale – Clinical Perspective

    Design Rationale – Clinical Perspective VLP Concept: • Plates are pre-bent and contourable. • As the plate is applied to bone, the fracture is compressed. • Acts as a spring to maintain compression • Standard PERI-LOC™ plates are too thick to offer this feature. Original Plate Contour

  55. Slide 55: Design Rationale – Market Perspective

    Slide 55: Design Rationale – Market Perspective

    Design Rationale – Market Perspective **

  56. Slide 56: VLP Advantages

    Slide 56: VLP Advantages

    VLP Advantages Low profile Most plates are 3.5-4.5 mm thick Maximal strength for OTA A or C Allow for locking technology Bulky Often prominent or painful Soft-tissue problems

  57. Slide 57: VLP Advantages

    Slide 57: VLP Advantages

    VLP Advantages Low profile VLP plates 2 mm thick Plenty of strength for partial fractures (OTA B)) Buttress effect ≤2.0mm

  58. Slide 58: VLP Advantages

    Slide 58: VLP Advantages

    VLP Advantages Anatomically contoured “Perfect” fit Screw paths optimized More screw holes available

  59. Slide 59: VLP Advantages

    Slide 59: VLP Advantages

    VLP Advantages Anatomically contoured Many plates are straight Useful in many regions Must be bent to fit in surgery Improper bend misaligns fracture

  60. Slide 60: VLP Summary

    Slide 60: VLP Summary

    VLP Summary Low profile Anatomically contoured Locking screw capabilities

  61. Slide 61: VLP Advantages

    Slide 61: VLP Advantages

    VLP Advantages Locking screw options Mechanically stronger than traditional screws Variable angle: surgeon’s choice of screw path Osteoporotic bone, complex fractures

  62. Slide 62: MT Tibial Plateau

    Slide 62: MT Tibial Plateau

    MT Tibial Plateau 56 yo woman Fell off stepladder

  63. Slide 63: MT Tibial Plateau

    Slide 63: MT Tibial Plateau

    MT Tibial Plateau 56 yo woman Fell off stepladder

  64. Slide 64: MT Tibial Plateau

    Slide 64: MT Tibial Plateau

    MT Tibial Plateau 56 yo woman Fell off stepladder

  65. Slide 65: BW Ankle

    Slide 65: BW Ankle

    BW Ankle 400 lb man Diabetic Sleep Apnea Venous stasis Injury films

  66. Slide 66: ER in Charge

    Slide 66: ER in Charge

    ER in Charge Reduced by ER Doc and splinted “Post-reduction” Xray …picked a bad day to get hurt…

  67. Slide 67: Now Its My Turn….

    Slide 67: Now Its My Turn….

    Now Its My Turn…. The next AM….

  68. Slide 68: Lets wait on this…..

    Slide 68: Lets wait on this…..

    Lets wait on this….. To OR ASAP for EX Fix

  69. Slide 69: 2 weeks later…..

    Slide 69: 2 weeks later…..

    2 weeks later….. Soft tissues are back to their usual miserable state….

  70. Slide 70: Plate in

    Slide 70: Plate in

    Plate in

  71. Slide 71

    Slide 71

  72. Slide 72

    Slide 72

  73. Slide 73

    Slide 73

  74. Slide 74: EXOGEN™ is #1 in Long Bone Stimulation

    Slide 74: EXOGEN™ is #1 in Long Bone Stimulation

    EXOGEN™ is #1 in Long Bone Stimulation EXOGEN 4000+™ Only stimulation product approved for the treatment of certain fresh fractures as well as nonunions • Speeds healing of certain fresh fractures by 38%* • Only ultrasound stimulation product • Known mechanism of action • New EXOGEN products in deve

  75. Slide 75: Joint Fluid Therapy products

    Slide 75: Joint Fluid Therapy products

    Joint Fluid Therapy products SUPARTZ™ is #2 in US Joint Fluid Therapy Q-MED’s DUROLANE® • Only single-injection JFT available in world for knee and hip OA* – Fermented (non-avian sourced) – Low volume but high molecular weight • Will appeal to a larger group of patients that may not want multiple kn

  76. Slide 76: Outpatient spine

    Slide 76: Outpatient spine

    Outpatient spine • Currently working through upgrades to the IDET product line • Launched SPINE-FIX™ in October – Only cement available with hydroxyapatite • Vertebroplasty market growing at 15%*; reimbursement established – and increasing IDET™ Treatment for Discogenic Low SPINE-FIX™ Back Pain Vert

  77. Slide 77: Continuum of care includes biologics

    Slide 77: Continuum of care includes biologics

    Continuum of care includes biologics • $3.5B very fragmented, early stage market • Sharpen strategic focus of research, regulatory, and BD • Leveraging the unique York, UK campus • Coordinate and commercialize the science • Projects include: • Q-Med collaboration on OA • Polynovo • Regenerative Medi

  78. Slide 78: What to watch for in 2008

    Slide 78: What to watch for in 2008

    What to watch for in 2008 CAPTION™ New Products that will drive growth – PERI-LOC™ VLP – JET-X™ Freedom and Quick Clamps – CAPTION™ Disposable Platelet Concentrator PERI-LOC™ VLP – EXOGEN™ line extensions – SPINE-FIX™ and outpatient spine business Core products that drive sustainability – TRIGEN™ IN

  79. Slide 79: Orthopaedic Reconstruction

    Slide 79: Orthopaedic Reconstruction

    Orthopaedic Reconstruction Joseph DeVivo, President 29

  80. Slide 80: Continuum of care

    Slide 80: Continuum of care

    Continuum of care >t smith&nephew Being part of the orthopedic surgeon's daily life | c Disease Treatment options Product REPAIR UILD REB Knee instability after Revision Operation LEGION® REVISION KNEE total replacement collateral ligaments affected | RT-MODULAR SOLUTION a RESTORE Knee pain after |

  81. Slide 81: Active patient market segment

    Slide 81: Active patient market segment

    Active market Active patient market segment Total Primary Hip/Knee Procedures under 64* Active patients driving growth 50% • Active, informed segment growing 40% faster than the traditional market Percentage of total 41% 30% 35% • Resonates with surgeons 20% 26% 10% • Demographics will continue to 0

  82. Slide 82: 2007 Success and Update

    Slide 82: 2007 Success and Update

    2007 Success and Update • BIRMINGHAM HIP™ Resurfacing System • JOURNEY™ DEUCE™ Bi-Compartmental System 2008 Product Highlights R3™ PROMOS™ PiGALILEO™ VERILAST™ Advanced Acetabular System Shoulder Navigation System Bearings Technology ™Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off.

  83. Slide 83: BHR™ system update

    Slide 83: BHR™ system update

    BHR™ system update • Continuing to train surgeons • Market experiencing growth and expansion • Realizing pull through business in core hips and knees • Birmingham Mid Head Resection (BMHR) ™Trademark of Smith & Nephew. 33

  84. Slide 84: Australian Joint Replacement Registry Hip Resurfacing Results

    Slide 84: Australian Joint Replacement Registry Hip Resurfacing Results

    Australian Joint Replacement Registry Hip Resurfacing Results Dr. Michael Solomon

  85. Slide 85: BHR™ competitive advantage

    Slide 85: BHR™ competitive advantage

    BHR™ competitive advantage Important Points to note from Australian registry: • The BHR system has follow-up from the inception of the registry in 1999 with over 6773 implantations. • A revision rate of 0.8 per 100 component years (total number x cumulative years implanted / revisions). • Corin has

  86. Slide 86: JOURNEY™ DEUCE™ surgeon perspective

    Slide 86: JOURNEY™ DEUCE™ surgeon perspective

    JOURNEY™ DEUCE™ surgeon perspective: Dr James Bresch, Des Plaines, IL • The JOURNEY DEUCE system is the only option for bi-compartmental OA that offers UKA benefits – normal feeling, motion and bone preservation – in a situation that would typically be treated with a traditional TKA • ACL and PCL re

  87. Slide 87: JOURNEY™ DEUCE™ clinical experience

    Slide 87: JOURNEY™ DEUCE™ clinical experience

    JOURNEY™ DEUCE™ clinical experience: • New product to treat a common problem • Retain cruciate ligaments • Utilization of M.I.S. • Quicker recovery, less pain ™Trademark of Smith & Nephew. Reg. US Pat. & TM Off. 37

  88. Slide 88: Active JOURNEY™ DEUCE™ Patient

    Slide 88: Active JOURNEY™ DEUCE™ Patient

    Active JOURNEY™ DEUCE™ Patient: Chris Patterson-Duebner “At this stage in life, I wasn’t going to be happy with just being able to walk. I’m going to be able to ski again, I can bike ride, I can garden, I can do deep-knee bends.” 38

  89. Slide 89: R3™ Acetabular System

    Slide 89: R3™ Acetabular System

    R3™ Acetabular System Not Approved for use in US • Accommodates multiple bearing options • Features STIKTITE™ porous coating designed to enhance fixation • Optimized inserts accommodate larger head sizes • Bearings provide foundation for wear reduction and achieves greater range of motion • Single s

  90. Slide 90: PROMOS™ Shoulder

    Slide 90: PROMOS™ Shoulder

    PROMOS™ Shoulder Complete Shoulder System • Addition from Plus provides a strong offering • Primary cemented & cementless • Reverse shoulder (Europe) • Resurfacing / Shoulder Cap in development • Advanced Glenoid options • Fully modular system with in-situ anatomical reconstruction • Ability to conv

  91. Slide 91: PiGALILEO™ Surgical Navigation

    Slide 91: PiGALILEO™ Surgical Navigation

    PiGALILEO™ Surgical Navigation • Image free and optimized for orthopaedic surgery • Dedicated to Smith & Nephew/Plus implants TKR, THR • Best workflow in the industry: minimal additional OR time • Strong interdisciplinary background • 30,000 mini robot surgeries • Marking leading technology • Roboti

  92. Slide 92: VERILAST™ Advanced Bearings Technology

    Slide 92: VERILAST™ Advanced Bearings Technology

    VERILAST™ Advanced Bearings Technology • VERILAST is the only TKR technology that provides dramatic reductions in wear Depuy Zimmer S&N Stryker S&N XLK Prolong GII-CoCr X3 Verilast • VERILAST technology marries two independent wear reducing technologies, namely OXINIUM femoral components and crossli

  93. Slide 93: 2008 Focus

    Slide 93: 2008 Focus

    2008 Focus New Products 2008 Core Products 2008 • R3™ Acetabular Cup System (US, EU) • JOURNEY™ Active Knee Solutions • LEGION™ XLPE (US, EU, AUS) • LEGION™ Revision Knee System • BHR™ Mid Head Resection (EU, AUS) • ANTHOLOGY™ Hip System • LEGION™ Hinge (US, AUS, EU) Visit us at Booths 4546 and 4246

  94. Slide 94: We are smith&nephew

    Slide 94: We are smith&nephew

    o/. 7.4 We are smith&nephew

Source: Internet Archive copy of global.smith-nephew.com

More decks from Smith & Nephew plc

All 131 Smith & Nephew decks