CorMedix Inc. · NASDAQ:CRMD

CorMedix — 21st Annual H.C. Wainwright Global Investment Conference (September 2019)

23 slides from CorMedix's conference presentation, Sep 9, 2019

  1. Slide 1: Harnessing Taurolidine Technology

    HarnessingTaurolidine Technology Leading Development of Novel Anti-Infective Products in the Era of Increasing Bacterial Resistance 21st Annual H.C. Wainwright Global Investment Conference September 9, 2019 CORMEDIX 1

  2. Slide 2: Forward-Looking Statements

    FORWARD-LOOKING STATEMENTS This presentation contains certain statements that constitute forward-looking statements within the meaning of the federal securities laws. Statements that are not historical facts, including statements about our beliefs and expectations, are forward-looking statements. Th

  3. Slide 3: Financial Summary

    FINANCIAL SUMMARY Founded January 2006 Exchange: Ticker NYSE American: CRMD Headquarters Berkeley Heights, NJ Employees (U.S.) 23 Common Stock O/S 23.8 Million Pref/CS Equivalents 6.1 Million Warrants Outstanding 2.3 Million Cash at June 30, 2019 $26.4 Million Recent Share Price $7.93 Recent Market

  4. Slide 4: Mission Statement

    MISSION STATEMENT To harness our taurolidine technology for the prevention and treatment of infectious, inflammatory, and other serious diseases First commercial product candidate in the US: Neutrolin® A novel, non-antibiotic antimicrobial solution designed to prevent costly and dangerous bloodstrea

  5. Slide 5: Corporate Highlights

    CORPORATE HIGHLIGHTS NEUTROLIN SIGNIFICANT MARKET OPPORTUNITY Non-antibiotic antimicrobial solution designed to prevent costly and Current estimates of annual need for catheter lock solutions in the U.S. for dangerous bloodstream infections associated with the use of central hemodialysis alone are a

  6. Slide 6: Commercial Opportunity

    COMMERCIAL OPPORTUNITY Neutrolin’s U.S. commercial opportunity as a catheter lock solution for hemodialysis and additional indications SIGNIFICANT UNMET NEED MARKET SIZE • Over 180 extensive interviews with nephrologists, oncologists, TPN healthcare providers have reconfirmed significant unmet need

  7. Slide 7: Key Benefits of Neutrolin

    KEY BENEFITS OF NEUTROLIN® NEUTROLIN® Non-antibiotic Anti-infective To Prevent CRBSI Prevents and reduces bloodstream infection. Bacteria and fungi, Antibiotic- NEUTROLIN® resistant strains, No reported resistance in Proprietary Formulation a clinical setting Taurolidine – 1.35% (anti-infective, ant

  8. Slide 8: FDA Recognizes Potential of Neutrolin

    FDA RECOGNIZES POTENTIAL OF NEUTROLIN APPROVAL PATHWAY Designated an investigational new drug by FDA (Catheter LOCK Solution Investigational Trial) 10.5 YEARS Granted New Chemical Entity (NCE) Status 5 years exclusivity Potential Market Exclusivity Granted Qualified Infectious Disease Product (QIDP)

  9. Slide 9: Medical Opportunity

    MEDICAL OPPORTUNITY Despite improvements and initiatives to control infection, catheter biofilm develops within 24 hours and can lead to life-threatening infections, costing the U.S. healthcare system billions of dollars annually SIGNIFICANT UNMET NEED 250,000 catheter-related bloodstream infections

  10. Slide 10: Neutrolin: Non-antibiotic Anti-infective to Prevent CRBSI

    NEUTROLIN® Non-antibiotic Anti-infective To Prevent CRBSI NO MICROBIAL RESISTANCE SHOWN BROAD SPECTRUM OF TAUROLIDINE COVERAGE Adaptation of microorganisms to taurolidine has Gram Positive Microorganisms not yet emerged as a factor in the pathogenesis Coagulase-negative Staphylococcus species and of

  11. Slide 11: LOCK-IT-100 Preventing CRBSI in Dialysis Patients

    LOCK-IT 100 PREVENTING CRBSI IN DIALYSIS PATIENTS DESIGN OBJECTIVE PRIMARY ENDPOINT SECONDARY ENDPOINTS Phase 3, multicenter, double- Demonstrate the efficacy and Time to occurrence of CRBSI Catheter patency blind, randomized (1:1), active safety of Neutrolin® as a control (heparin) catheter lock so

  12. Slide 12: LOCK-IT-100 Baseline Demographics (I)

    LOCK-IT 100 BASELINE DEMOGRAPHICS (l) Demographic Neutrolin (403) % Heparin (403) % Mean age (years) (SD) 60.8 (14.22) 60.9 (14.39) <65 years (%) 59.3 58.6 ≥ 65 to < 75 years (%) 24.6 23.6 ≥ 75 years (%) 16.1 17.9 Female (%) 45.7 38.2 White (%) 61.5 65.0 Black or African-American (%) 31.3 27.8 Asian

  13. Slide 13: LOCK-IT-100 Baseline Demographics (II)

    LOCK-IT 100 BASELINE DEMOGRAPHICS (ll) Demographic Neutrolin (403) % Heparin (403) % Diabetes (%) 69.0 68.7 BMI (mean) kg/m2 29.7 29.2 Months Since 1st Dialysis (SD) 21.2 (37.5) 19.8 (37.0) ≤ 12 Months on Dialysis (%) 67.5 68.5 Internal Jugular CVC (%) 92.1 90.6 Subclavian CVC (%) 7.4 7.7 Other CVC

  14. Slide 14: Topline Results of LOCK-IT-100 Study

    TOPLINE RESULTS OF LOCK-IT 100 STUDY Interim Analysis Full Study Total CRBSIs 28 41 Total Subjects 653 795 Neutrolin Reduced CRBSIs by: 72% 71% Neutrolin (control) Event Rates* 0.136 (0.491) 0.133 (0.465) p-value 0.0034 0.0006 0.6 0.6 0.5 -72% 0.5 -71% 0.4 0.4 0.3 0.3 c c 0.2 0.2 0.1 0.1 0 0 Neutrol

  15. Slide 15: Secondary Endpoints: No Statistically Significant Differences

    SECONDARY ENDPOINTS: NO STATISTICALLY SIGNIFICANT DIFFERENCES BETWEEN NEUTROLIN & CONTROL ARMS Catheter Removal: p=0.416 v Neutrolin (n=397) Control Arm (n=398) Event Rate* 3.48 3.23 Subjects 236 out of 397 225 out of 398 Loss of Catheter Patency: p=0.12 v Neutrolin Control Arm Event Rate* 0.99 0.74

  16. Slide 16: LOCK-IT-100 Secondary Endpoint

    LOCK-IT 100 SECONDARY ENDPOINT Catheter Removal for Positive Reasons Full Population Analysis at 41 CRBSIs Post-Hoc Neutrolin Heparin (N=397) (N=398) No Longer Needed for HD 162 131 Improved Renal Function 0 1 Total Removals-Positive Reasons 162 (41) 132 (33) Total Catheter-Days Follow-up 67,780 69,

  17. Slide 17: LOCK-IT-100 Secondary Endpoint

    LOCK-IT 100 SECONDARY ENDPOINT Catheter Removal for Negative Reasons Full Population Analysis at 41 CRBSIs Post-Hoc Neutrolin Heparin (N=397) (N=398) CRBSI (%) 8 (2.0) 29 (7.3) All Cath. Malfunction-Dysfunction (%) 62 (16) 57 (14) Other (%) 4 (1.0) 7 (1.8) Total 74 (19) 93 (23) Total Catheter-Days F

  18. Slide 18: LOCK-IT-100 Secondary Endpoint

    LOCK-IT 100 SECONDARY ENDPOINT Loss of Catheter Patency Full Population Analysis at 41 CRBSIs Post-Hoc Neutrolin (N=397) Heparin (N=398) (%) (%) Loss of Catheter Patency (%) 63 (16) 48 (12) rt-PA for Loss of Patency (%) 46 (12) 33 (8.3) CR for Loss of Patency (%) 17 (4.3) 15 (3.8) Total Catheter Day

  19. Slide 19: LOCK-IT-100 Safety

    LOCK-IT 100 SAFETY Treatment Emergent Serious Adverse Events Incidence ≥2% in Either Treatment Arm (Safety Population) Deaths & AE Preferred Terms Neutrolin (N=398) % Heparin (N=399) % Deaths 4.5 5.3 Device-related Infection 1.5 2.0 Pneumonia 3.0 5.3 Sepsis 2.3 3.5 Acute Myocardial Infarction 1.3 3.

  20. Slide 20: Conclusion

    CONCLUSION LOCK-IT-100, a landmark study, showed that in ESRD subjects with hemodialysis via a 01 central venous catheter, Neutrolin® catheter lock solution significantly reduced catheter- related bloodstream infections, a leading cause of mortality in HD Compared to heparin, there was no significan

  21. Slide 21: CorMedix Management Team

    CORMEDIX MANAGEMENT TEAM Khoso Baluch Chief Executive Officer Robert Cook Chief Financial Officer Phoebe Mounts, EVP and General Counsel PhD, JD Paul Chew, MD Chief Medical Officer Jack Armstrong EVP Technical Operations Elizabeth Masson EVP & Head Of Clinical Operations CORMEDIX 21

  22. Slide 22: Current CorMedix Pipeline

    CURRENT CORMEDIX PIPELINE DRUG PIPELINE Product Category Indication Preclinical Phase 1 Phase 2 Phase 3 Marketed Hemodialysis Stopped for Efficacy at Interim Review: FDA Discussions Ongoing Neutrolin® U.S. Oncology ICU / CCU CMDX-001 Pediatric Neuroblastoma* * Orphan Drug Designation MEDICAL DEVICE

  23. Slide 23: Thank You

    NYSE American: CRMD @CorMedixInc THANK @Investor & Media Contacts LifeSci Advisors, LLC Dan Ferry YOU [email protected] 617-535-7746 400 Connell Drive Suite 5000 Berkeley Heights, NJ 908.517.9500 CORMEDIX 23

CorMedix — 21st Annual H.C. Wainwright Global Investment Conference (September 2019) on 6ix