Arcoma Ab — Technical Presentation (April 2022)

19 slides from Arcoma Ab's technical presentation, Apr 25, 2022

  1. Slide 1: Arcoma Application Webinar: OMNERA 500A / ACESO+ SW Update

    WORLD CLASS DIGITAL X-RAY SYSTEMS 2022-04-25 ARCOMA APPLICATION WEBINAR OMNERA 500A / ACESO+ SW UPDATE – New features (Reference: SI_2022_121_1000 i5)

  2. Slide 2: New Software Release - Improved Workflow

    NEW SOFTWARE RELEASE - IMPROVED WORKFLOW • Faster positioning for Wall stand examinations with tilted detector • Improved workflow for dedicated Chest X-ray rooms • SW version info in display • Increased stability

  3. Slide 3: Faster positioning for wall stand examinations with tilted detector

    Faster positioning for Wall stand examinations with tilted detector CURRENT NEW • Protocol selected and autoposition activated. • Protocol selected and autoposition activated. • If the detector is too high for the tube to reach the • System automatically correct position the adjust the detector posi

  4. Slide 4: Faster positioning for wall stand examinations with tilted detector

    Faster positioning for Wall stand examinations with tilted detector ➢ More automated and supporting operation ➢ Saves time ➢ Smoother workflow

  5. Slide 5: Workflow: Same Patient

    WORKFLOW SAME PATIENT > RE-POSITIONING NEED MINIMIZED > EFFICIENT WORKFLOW NEWS No need to reposition between exposures were top (or bottom) centered collimation selected. No need to reposition between exposures were an autopositioning wall stand detector is used.

  6. Slide 6: Workflow: Between Patients

    WORKFLOW BETWEEN PATIENTS > RE-POSITIONING NEED MINIMIZED > EFFICIENT WORKFLOW NEWS Servo remains active between patients. > You can define that servo shall remain active also between patients, under the condition that the same position is used also for next patient.

  7. Slide 7: Chest Room Improvements: Top/Bottom-centring (current workflow)

    CURRENT WORKFLOW CHEST ROOM Improvements: Top/Bottom-centring 1 PROTOCOL selected + 2 ADJUST COLLIMATOR 3 EXPOSURE 7 OTC position + collimator 8 ADJUST COLLIMATOR activated, servo active FIELD FOR PATIENT, field size from protocol. FIELD FOR PATIENT servo active OTC will move. READY FOR NEXT EXPOSUR

  8. Slide 8: Chest Room Improvements: Top/Bottom-centring (new workflow)

    NEW WORKFLOW CHEST ROOM Improvements: Top/Bottom-centring 1 PROTOCOL selected + 2 ADJUST COLLIMATOR 3 EXPOSURE 5 SERVO STAYS ACTIVE activated, servo active FIELD FOR PATIENT, Collimator field size kept servo active SYSTEM READY. READY FOR NEXT EXPOSURE 4 NEXT PROTOCOL SELECTED (manual or automatic)

  9. Slide 9: Chest Room Improvements: Autopositioning detector (current workflow)

    CURRENT WORKFLOW CHEST ROOM Improvements: Autopositioning detector 1 PROTOCOL selected + 2 ADJUST DETECTOR 3 EXPOSURE 7 OTC & Detector moves to 8 ADJUST DETECTOR activated, detector HEIGTH FOR PATIENT, programmed height HEIGHT FOR PATIENT moves to programmed servo active servo active Servo active he

  10. Slide 10: Chest Room Improvements: Autopositioning detector (new workflow)

    NEW WORKFLOW CHEST ROOM Improvements: Autopositioning detector 1 PROTOCOL selected + 2 ADJUST DETECTOR 3 EXPOSURE 5 OTC & Detector moves to activated, detector HEIGTH FOR PATIENT, programmed height moves to programmed servo active servo active height. servo active READY FOR EXPOSURE 4 NEXT PROTOCOL

  11. Slide 11: Between Patients

    BETWEEN PATIENTS SERVO CAN STAY ACTIVE BETWEEN PATIENTS SAME POSITION? YES > SERVO ACTIVE YES? > SERVO ACTIVE SYSTEM INSTANTLY READY

  12. Slide 12: New Software Release - SW Version Info

    NEW SOFTWARE RELEASE - SW VERSION INFO SW version for the complete SW package directly on the tube display / System setting menu.

  13. Slide 13: New Software Release - Improved Workflow

    NEW SOFTWARE RELEASE - IMPROVED WORKFLOW ➢ Smart positioning – Increased system automation ➢ System instant ready for next exposure ➢ System instant ready for next patient

  14. Slide 14: Application: Settings for New Features

    APPLICATION SETTINGS FOR NEW FEATURES

  15. Slide 15: Settings - Overview

    SETTINGS - OVERVIEW Update Setting performed to activate Tilted detector, automatic No settings needed, vertical movement basic feature Collimator centring Canon Protocol Editor Top/Bottom/Center Autopositioning Wall stand Arcoma Service program detector Servo active between patients Arcoma Service

  16. Slide 16: Chest Room Improvements: Top/Bottom-centring

    CHEST ROOM Improvements: Top/Bottom-centring CANON PROTOCOL SETTING > Select collimator centring COLLIMATION CENTERING SETTING • Top / Center / Bottom Default setting can be changed when needed by the user from the tube display.

  17. Slide 17: Auto positioning Wall stand detector

    Auto positioning Wall stand detector ARCOMA SERVICE PROGRAM ➢ ACTIVATE Auto positioning Wall stand detector. Height of detector is defined when the autoposition is defined.

  18. Slide 18: Servo active between patients

    Servo active between patients ARCOMA SERVICE PROGRAM SAME POSITION? SAME POSITION? YES > SERVO ACTIVE YES > SERVO ACTIVE

  19. Slide 19: Thank You