Slide 1: Arcoma Application Webinar: OMNERA 500A / ACESO+ SW Update
WORLD CLASS DIGITAL X-RAY SYSTEMS 2022-04-25 ARCOMA APPLICATION WEBINAR OMNERA 500A / ACESO+ SW UPDATE – New features (Reference: SI_2022_121_1000 i5)
Slide 2: New Software Release - Improved Workflow
NEW SOFTWARE RELEASE - IMPROVED WORKFLOW • Faster positioning for Wall stand examinations with tilted detector • Improved workflow for dedicated Chest X-ray rooms • SW version info in display • Increased stability
Slide 3: Faster positioning for wall stand examinations with tilted detector
Faster positioning for Wall stand examinations with tilted detector CURRENT NEW • Protocol selected and autoposition activated. • Protocol selected and autoposition activated. • If the detector is too high for the tube to reach the • System automatically correct position the adjust the detector posi
Slide 4: Faster positioning for wall stand examinations with tilted detector
Faster positioning for Wall stand examinations with tilted detector ➢ More automated and supporting operation ➢ Saves time ➢ Smoother workflow
Slide 5: Workflow: Same Patient
WORKFLOW SAME PATIENT > RE-POSITIONING NEED MINIMIZED > EFFICIENT WORKFLOW NEWS No need to reposition between exposures were top (or bottom) centered collimation selected. No need to reposition between exposures were an autopositioning wall stand detector is used.
Slide 6: Workflow: Between Patients
WORKFLOW BETWEEN PATIENTS > RE-POSITIONING NEED MINIMIZED > EFFICIENT WORKFLOW NEWS Servo remains active between patients. > You can define that servo shall remain active also between patients, under the condition that the same position is used also for next patient.
Slide 7: Chest Room Improvements: Top/Bottom-centring (current workflow)
CURRENT WORKFLOW CHEST ROOM Improvements: Top/Bottom-centring 1 PROTOCOL selected + 2 ADJUST COLLIMATOR 3 EXPOSURE 7 OTC position + collimator 8 ADJUST COLLIMATOR activated, servo active FIELD FOR PATIENT, field size from protocol. FIELD FOR PATIENT servo active OTC will move. READY FOR NEXT EXPOSUR
Slide 8: Chest Room Improvements: Top/Bottom-centring (new workflow)
NEW WORKFLOW CHEST ROOM Improvements: Top/Bottom-centring 1 PROTOCOL selected + 2 ADJUST COLLIMATOR 3 EXPOSURE 5 SERVO STAYS ACTIVE activated, servo active FIELD FOR PATIENT, Collimator field size kept servo active SYSTEM READY. READY FOR NEXT EXPOSURE 4 NEXT PROTOCOL SELECTED (manual or automatic)
Slide 9: Chest Room Improvements: Autopositioning detector (current workflow)
CURRENT WORKFLOW CHEST ROOM Improvements: Autopositioning detector 1 PROTOCOL selected + 2 ADJUST DETECTOR 3 EXPOSURE 7 OTC & Detector moves to 8 ADJUST DETECTOR activated, detector HEIGTH FOR PATIENT, programmed height HEIGHT FOR PATIENT moves to programmed servo active servo active Servo active he
Slide 10: Chest Room Improvements: Autopositioning detector (new workflow)
NEW WORKFLOW CHEST ROOM Improvements: Autopositioning detector 1 PROTOCOL selected + 2 ADJUST DETECTOR 3 EXPOSURE 5 OTC & Detector moves to activated, detector HEIGTH FOR PATIENT, programmed height moves to programmed servo active servo active height. servo active READY FOR EXPOSURE 4 NEXT PROTOCOL
Slide 11: Between Patients
BETWEEN PATIENTS SERVO CAN STAY ACTIVE BETWEEN PATIENTS SAME POSITION? YES > SERVO ACTIVE YES? > SERVO ACTIVE SYSTEM INSTANTLY READY
Slide 12: New Software Release - SW Version Info
NEW SOFTWARE RELEASE - SW VERSION INFO SW version for the complete SW package directly on the tube display / System setting menu.
Slide 13: New Software Release - Improved Workflow
NEW SOFTWARE RELEASE - IMPROVED WORKFLOW ➢ Smart positioning – Increased system automation ➢ System instant ready for next exposure ➢ System instant ready for next patient
Slide 14: Application: Settings for New Features
APPLICATION SETTINGS FOR NEW FEATURES
Slide 15: Settings - Overview
SETTINGS - OVERVIEW Update Setting performed to activate Tilted detector, automatic No settings needed, vertical movement basic feature Collimator centring Canon Protocol Editor Top/Bottom/Center Autopositioning Wall stand Arcoma Service program detector Servo active between patients Arcoma Service
Slide 16: Chest Room Improvements: Top/Bottom-centring
CHEST ROOM Improvements: Top/Bottom-centring CANON PROTOCOL SETTING > Select collimator centring COLLIMATION CENTERING SETTING • Top / Center / Bottom Default setting can be changed when needed by the user from the tube display.
Slide 17: Auto positioning Wall stand detector
Auto positioning Wall stand detector ARCOMA SERVICE PROGRAM ➢ ACTIVATE Auto positioning Wall stand detector. Height of detector is defined when the autoposition is defined.
Slide 18: Servo active between patients
Servo active between patients ARCOMA SERVICE PROGRAM SAME POSITION? SAME POSITION? YES > SERVO ACTIVE YES > SERVO ACTIVE