Uscom Limited · ASX:UCM

Uscom — Investor Presentation (April 2014)

28 slides from Uscom's investor presentation, April 2014

  1. Slide 1: USCOM: Hemodynamics Fluid Innovation

    USCOM 1A Hemodynamics Fluid Innovation www.uscom.com.au The Measure of Life

  2. Slide 2: What is USCOM?

    What is USCOM? Totally Noninvasive Monitor for Individualized Hemodynamic Management • Identify illness • Predict fluid responsiveness • Trend therapy response • Improve outcome Clinical Gold Standard www.uscom.com.au The Measure of Life

  3. Slide 3: Why USCOM?

    Why USCOM? Totally Noninvasive, Safe, Portable, Fast • Identify illness • Clarify hemodynamic status • Predict fluid responsiveness • SVI & SMII / SVV / FTc / PLR • Trend therapy response • Direct appropriate treatment • Improve outcome • Individual Optimization www.uscom.com.au The Measure of Life

  4. Slide 4: Individualize Resuscitation

    Individualize Resuscitation • Stroke Volume Index • Sensitive and responsive to circulatory change • SMII (Unique to USCOM) • Safe, one-step fluid responsiveness • Distinguish low inotropy from low preload • Rapid optimization of fluid management and drug titration www.uscom.com.au The Measure of Li

  5. Slide 5: SMII – Preload and Afterload Independent

    SMII – Preload and Afterload Independent SV and SMII after 5ml/Kg Rapid IV Fluid Infusion Between measures 6 and 7 a completely stable and unstimulated patient with an implanted pacemaker and a fixed heart rate of 60 per minute was given 5ml/kg of fluid over a 10 minute period. All other readings we

  6. Slide 6: Fluid Responsiveness Predictive

    Fluid Responsiveness Predictive www.uscom.com.au The Measure of Life

  7. Slide 7: Low SVI, Low Inotropy

    Low SVI, Low Inotropy X SMII 0.8 • Negative fluid responsiveness: SVI < 35 ml/m2 & SMII < 1.1 W/m2 www.uscom.com.au The Measure of Life

  8. Slide 8: Individualize Optimization

    Individualize Optimization • Predict safe fluid responsiveness • Guide and manage therapy Fluid Diuretic Inotrope Vaso +ve Dilator -ve Constrictor The Frank-Starling curve www.uscom.com.au The Measure of Life

  9. Slide 9: Monitoring Features

    Monitoring Features • One modality, one position • CW Doppler at Aortic or Pulmonary Valve • LVOT diameter anthropometric algorithm • Improves reproducibility and sensitivity • Option to override with echo measure • Multiple beats per measure automatically traced • Improves sensitivity • All traced

  10. Slide 10: Monitoring Features

    Monitoring Features • Beat to beat hemodynamic parameters: SV, CO, SVR,* SMII,* FTc, SVV, DO2* • Numerical or graphical display • SVV for fluid responsiveness • Traced beats of one or two full respiratory cycles • SMII systolic power of the heart • Preload and afterload independent. • High correlati

  11. Slide 11: How USCOM Works

    How USCOM Works Click image to play movie http://youtu.be/ZOUr8WOfxrc www.uscom.com.au The Measure of Life

  12. Slide 12: CW Doppler Ultrasound

    CW Doppler Ultrasound • Accurate • Reproducible • Sensitive • Safe Measures blood velocity and volume www.uscom.com.au The Measure of Life

  13. Slide 13: Flow Area

    Flow Area • Flow area (OTD) determined by Algorithm • Linear relationship with Height • Neonates (<50cm/20ins) Weight Height → Area www.uscom.com.au The Measure of Life

  14. Slide 14: Calculating Flow

    Calculating Flow Stroke Volume = Valve area x Stroke distance Diameter Stroke Distance (OTD) (vti) Cardiac Output = Stroke Volume x Heart Rate www.uscom.com.au The Measure of Life

  15. Slide 15: DO2 – Oxygen Delivery

    DO2 – Oxygen Delivery • Manipulation of preload, afterload CI are and inotropy the means of optimizing perfusion Inotrop y www.uscom.com.au The Measure of Life

  16. Slide 16: Parameters of DO2

    Parameters of DO2 • Circulation  Cardiac Output (CO) • Preload  Stroke Volume (SV)  Stroke Volume Variation (SVV)  Flow Time corrected (FTc) • Inotropy  Inotropy Index (SMII) • Afterload  Systemic Vascular Resistance (SVR) • Perfusion  Oxygen Delivery (DO2) www.uscom.com.au The Measure of Lif

  17. Slide 17: Monitor with USCOM

    Monitor with USCOM Parameters are measured All parameters and data are real time, beat-to-beat trended and stored www.uscom.com.au The Measure of Life

  18. Slide 18: Clinical Units

    Clinical Units • Pediatric ICU • Obstetric Medicine • Hemodialysis • Neonatal ICU • Rapid Response • Drug trials • Adult ICU • Liver Transplantation • Animal research • Emergency • Step Down Unit • Electrophysiology • Anesthesiology • Cardiology • Sports Medicine • Oncology • Burns Unit • Veterinary

  19. Slide 19: Clinical Applications

    Clinical Applications • Fluid • Hypertension Responsiveness • Heart Failure • Fluid Status • Vasoconstriction • Systolic Function • Vasotherapy • Sepsis • Arrhythmias • Shock • Hypotension www.uscom.com.au The Measure of Life

  20. Slide 20: Clinical Value

    Clinical Value • Improve Care • Reduce Risk • Reduce Cost www.uscom.com.au The Measure of Life

  21. Slide 21: Improve Care

    Improve Care • Know the hemodynamic state • Accurate & sensitive • Direct appropriate therapy • Rational & Individual • Understand the effect of treatment • Trend change www.uscom.com.au The Measure of Life

  22. Slide 22: Reduce Risk

    Reduce Risk • First do no harm • Safer alternative to invasive and semi invasive • Avoid complications • Totally NON invasive • Deliver the right drug at the right time • Individualized management www.uscom.com.au The Measure of Life

  23. Slide 23: Reduce Cost

    Reduce Cost • Avoid operating costs • No consumables • Assess and intervene early • Portable, fast and easy to learn and use • Maximize investment • Multiple patient management www.uscom.com.au The Measure of Life

  24. Slide 24: Validation

    Validation • Historical validation of CW Doppler • Flowprobes in hemodynamic models & animals • Pulmonary artery catheter in animals and post cardiac surgical/heart failure • PiCCO / Pulmonary artery catheter in critically ill patients on vasotherapy and ventilated • Echo / MRI in clinical studies w

  25. Slide 25: Clinical Evidence

    Clinical Evidence • Fluid Optimization – “The change in SV with PLR was the only hemodynamic index with significant predictive ability” • Pediatric Sepsis – “Subsequent ICU hemodynamic support directed to goals of …… cardiac index of 3.3-6.6l/min/m2” • “The evolving haemodynamics of paediatric septi

  26. Slide 26: USCOM

    USCOM Totally Noninvasive Monitor for Individualized Hemodynamic Management • Identify illness • Predict fluid responsiveness • Trend therapy response • Improve outcome NEW Clinical Gold Standard www.uscom.com.au The Measure of Life

  27. Slide 27: USCOM Advantages

    USCOM Advantages Individualized Hemodynamic Management • Noninvasive and Reliable • Accurate and Validated • Adults, Children & Neonates • Critically ill and Well Patient • Hospital wide • Fast, Portable & Safe • Highly Economical www.uscom.com.au The Measure of Life

  28. Slide 28: The Measure of Life

    The Measure of Life www.uscom.com.au Uscom © 2013 - Revision 0002 The Measure of Life