  1. Slide 1: Dispelling the Myths of Heat Transfer Fluids

    Dispelling the Myths of Heat Transfer Fluids Kevin Connor – The Dow Chemical Company

  2. Slide 2: Heat Transfer – Chill Water Loop

    Heat Transfer – Chill Water Loop Secondary Coolant Primary Refrigerant (Heat Transfer Fluid) Expansion Device Air Handler Evaporator Condenser Pump Compressor 2

  3. Slide 3: The Need for “Antifreeze”

    The Need for “Antifreeze” • Water is almost a perfect fluid… – Excellent heat transfer – Excellent health & safety – Low cost • BUT water freezes at 0oC / 32oF • Antifreeze protects system piping and components from damage caused by freezing – Volume expansion due to ice crystals generates pressure

  4. Slide 4: Heat Transfer Fluid “Wish List”

    Heat Transfer Fluid “Wish List” • Effective freeze protection – Freezing point below -40oC / -40oF • Efficient heat transfer over broad temperature range – -15oC to 125oC / 0oF to 250oF • No harmful effects (health, safety, environment) – Non-toxic, non-flammable, environmentally benign • Non-corros

  5. Slide 5: Choice of Heat Transfer Fluids

    Choice of Heat Transfer Fluids • Salt based (brines) • Alcohols & Glycols – Lithium bromide ̶ Methanol – Calcium chloride ̶ Ethanol – Magnesium chloride ̶ Ethylene glycol – Sodium chloride ̶ Propylene glycol – Potassium acetate ̶ 1,3-propanediol – Potassium formate ̶ Glycerin – Potassium carbonate •

  6. Slide 6: Impact on Freezing Point

    Impact on Freezing Point Data from Melinder 2007 “Thermophysical Properties of Aqueous Solutions Used as Secondary Working Fluids “ 6

  7. Slide 7: Impact on Corrosion

    Impact on Corrosion 15% Methanol 15% Propylene Water Glycol 7

  8. Slide 8: Corrosion

    Corrosion • All salts are very corrosive – Long term protection is impossible even with corrosion inhibitors • Glycols or alcohols (without corrosion inhibitors) are corrosive to most metals – Oxidize to form acids  low pH  acidic pH is corrosive – Must use correct type of corrosion inhibitor tech

  9. Slide 9: Corrosion Control

    Corrosion Control • Corrosion can be limited by control of key environmental variables ̶ Design & Operation ̶ Materials ̶ Temperature & exposure to O2 ̶ Fluid Chemistry ̶ Corrosion inhibitors & pH ̶ Fluid purity • Maintain metal in passive rather than active state – Corrosion rate 1000 times lower

  10. Slide 10: Impact on System Efficiency

    * Data from Melinder 2007 Impact on System Efficiency “Thermophysical Properties of Aqueous Solutions Used as Secondary Working Fluids “ Physical Properties @ 10oC/ 50oF Thermal Volumetric Heat Fluid Description Freezing Point Conductivity Capacity Viscosity (cP) ( oC ) (W / m.K) (kJ / L.K) water 0

  11. Slide 11: System Performance

    System Performance • Adding antifreeze to water negatively impacts system performance – Must trade performance for freeze protection • Reduced heat transfer efficiency ̶ Antifreeze decreases thermal conductivity & specific heat ̶ How much will system performance be reduced? ̶ Regrettably there is no

  12. Slide 12: Impact on Health & Safety

    Impact on Health & Safety • Methanol and ethylene glycol are classified as moderately toxic – About 125 mLs is lethal dose for typical sized adult • Industrial ethanol (not for consumption) is denatured – Can contain methanol, pyridine or other (toxic) denaturants • Only propylene glycol is formally

  13. Slide 13: Fire Safety: Flash point temperature

    Fire Safety RCRA hazardous OSHA hazardous waste (ignitable) material (flammable) 122 115 Flash point temperature [deg F] 109 103 LFL “pure” ethanol = 4% 99 Flash pt = 13oC / 55oF 96 93 91 89 84 86 Trademark of The Dow Chemical Company 13

  14. Slide 14: Advantages of Using Glycol

    Advantages of Using Glycol Effective Freeze Protection Non-corrosive (if properly formulated) Relatively Efficient Heat Transfer No Adverse HS&E Effects Heath – Low toxicity (PG fluids) Safety – Non-flammable Environment – Readily Biodegradable Relatively Low Cost 14

  15. Slide 15: Advantages of Choosing Dow

    Advantages of Choosing Dow • Dow heat transfer fluids are properly formulated with corrosion inhibitors and pH buffers which ̶ Passivate metal surfaces  prevent corrosion ̶ Neutralize degradation compounds  prevent pH drop ̶ Thermoxidatively stable provide long term protection • Avoid cooling tow

  16. Slide 16: DOWTHERM™ SR-1 Fluid

    DOWTHERM™ SR-1 Fluid • Ethylene glycol-based fluid (95%) • Fluorescent pink • Efficient heat transfer – -28° to 120° C • Provides freeze / burst protection – -51° C / -60° C (depending on concentration) • Dow is the oldest back-integrated supplier of glycol based heat transfer fluids: – DOWTHERM™ SR

  17. Slide 17: DOWFROST™ Fluid

    DOWFROST™ Fluid • Propylene glycol-based fluid (96%) • Water white • Low toxicity – fully complies with FDA & NSF regulations – Made with DOW PuraGuard™ Propylene Glycol USP/EP • Efficient heat transfer – -18° to 120° C • Provides freeze / burst protection – -51° C / -60° C (depending on concentrati

  18. Slide 18: Advantages of DOW PuraGuard

    Advantages of DOW PuraGuardTM • DOWFROST™ is the only inhibited glycol made with DOW PuraGuard™ Propylene Glycol USP/EP, a pharmaceutical grade of monopropylene glycol with a specified purity of 99.8% or greater • Competitive products are made with lower quality PG ̶ Fluid lifetime & safety are comp

  19. Slide 19: DOWFROST™ HD Fluid

    DOWFROST™ HD Fluid • Propylene glycol-based fluid (94%) • Fluorescent yellow • Fortified inhibitor package versus regular DOWFROST™ – Does not have same FDA / NSF approval • Efficient heat transfer – -18° to 135° C • Provides freeze / burst protection – -51° C / -60° C (depending on concentration) •

  20. Slide 20: DOWFROST™ GEO 20

    DOWFROST™ GEO 20 • Propylene glycol-based fluid (20 vol%) – Fluorescent yellow • Designed for Geothermal Heat Pumps – Lower concentration means lower pumping cost & higher heat transfer efficiency – Excellent corrosion protection – Bio-static concentration (will not support bio-degradation / bio- fo

  21. Slide 21: Which Product Do I Choose?

    Which Product Do I Choose? • Ethylene glycol (EG) is moderately toxic – ~½ cup is lethal to an average size adult • Propylene glycol (PG) is essentially non-toxic – Approved by FDA as direct food additive • Use DOWFROST™ for low toxicity needs – Food processing (DOWFROST™ only) – Schools or hospital

  22. Slide 22: Avoid Poorly Formulated Products

    Avoid Poorly Formulated Products Metal Test ASTM Data Limit Copper 1.6 10 Solder 9.2 30 Brass 3.7 10 Steel 199 10 Cast Iron 297 10 Aluminum 88 30

  23. Slide 23: Tips for Proper Operation

    Tips for Proper Operation • Use purified water (distilled, de-ionized) for dilution • Install and maintain “correct” glycol concentration – Over-dilution  causes corrosion & bio-fouling – Too concentrated  causes poor heat transfer • Operate within recommended temperature ranges – Over-heating  c

  24. Slide 24: Water Quality

    Water Quality • Salts cause corrosion • Hardness causes scales & sludge • Requirements for dilution water ̶ Chlorides <25 ppm ̶ Sulfates <25 ppm ̶ Total hardness (as CaCO3) <100 ppm

  25. Slide 25: Over-Dilution

    Over-Dilution • Over-dilution causes corrosion and bio- fouling ̶ Glycol degradation ̶ Unpleasant odors • Minimum concentration ̶ 20% - 25% Bio-fouling - customer sample with • Maximum concentration 11% propylene glycol ̶ 60% - 65% 25

  26. Slide 26: Over-Heating

    Over-Heating • Fluid degradation and corrosion increase as temperature increase ̶ Fluid life compromised • Temperature limits ̶ Max bulk: 250 F to 350 F ̶ Max film: 300 F to 400 F Increased time / temperature, exposure to 02 / air

  27. Slide 27: Dow Analytical Service

    Dow Analytical Service • Free service if system contains more than 250 gallons of DOWTHERM™ SR-1 / DOWFROST™ • Sample analysis kits are available from Dow – “2 PAK’s” and “6 PAK’s” • Send samples to Dow laboratory and receive comprehensive analysis & report within 2 weeks • Detailed analysis: – Glyc

  28. Slide 28: Sample Kits

    Sample Kits Speer wren atu ne Fiurw ANALYSIS Krr Heat Transfer Fluids

  29. Slide 29: Example Report

    Example Report The DOW CHEMICAL COMPANY DOW FROST* Moat Trameter Flutie DOW FROST* Sample Analysis Repert —e Ramuyple Received. 01/04. 2002, TENAS OFPRATIONS, 2301 BRAZOSPORT Sample Number 2002-001-0036 EREEPORT. Togin Number (12-2062 0007 Report Date: Daa 2002 This is a copy of the report for: Dist

  30. Slide 30: The Bottom Line

    The Bottom Line • Glycol based fluids provide excellent overall protection • Understand the impact that glycol has on water • Trade off between performance versus freeze protection • Select and use a properly formulated glycol based fluid • Specifically designed for HVAC applications • Correctly ins

  31. Slide 31: www.dowfrost.com

    www.dowtrost.com Solutions for life.