Slide 1: Webinar April 27, 2016
Webinar April 27, 2016 Dennis L. Mater [email protected] FR Apparel Sales Technical Leader – North America 1 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 2: Webinar Overview
Electric Utility PPE Considerations Webinar Overview Arc Flash Understanding Applicable Utility Standards Applicable Standards Test Methods Importance of Wearer Protection Arc Rated PPE Burn Injuries PPE Considerations Comfort Life Cycle Care and Maintenance Actual Fabric Comparisons S
Slide 3: Electric Utility PPE Considerations
Electric Utility PPE Considerations 3 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 4: Introduction: Dangers for Electric Utility Workers
Electric Utility PPE Considerations Introduction Utility Line Work is Commonly Quoted as One of the Ten Most Dangerous Jobs in the U.S. OHSA Estimates: 74 fatalities and 444 serious injuries occur annually for those workers involved in electrical utility work. * Protection from the Unexpected – Hidd
Slide 5: Introduction: OSHA Arc-Flash Injury Reports
Electric Utility PPE Considerations Introduction Sample of Injury Reports from OHSA Database search for “arc-flash” or “burn” Terms with Voltage Information * Injuries reviewed at medium and high voltages A survey was conducted of 40 patients treated for electrical work injuries Most patients ha
Slide 6: Electric Utility PPE Considerations
Electric Utility PPE Considerations 6 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 7: Arc Flash Basics
Electric Utility PPE Considerations Arc Flash Basics Physical arc is created when electricity conducts unpredictably between exposed phases or to a ground Arc flash can occur in low voltage (LV) and high voltage (HV) electrical systems Arc flash events can be caused by: Human error or improper tra
Slide 8: An Arc Event Presents Many Types of Hazards
Electric Utility PPE Considerations An Arc Event Presents Many Types of Hazards Intense Radiant and Convective Energy > 1.5 cal/cm2 2nd & 3rd Degree Burns for Unprotected Skin Ignition of Non-FR Clothing Typically Short Duration Events Molten Metal / Hot Gases / Smoke Secondary Fire (Area Equipm
Slide 9: Electric Utility PPE Considerations
Electric Utility PPE Considerations 9 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 10: Overview – Industry Standards: OSHA 1910.269
Electric Utility PPE Considerations Overview – Industry Standards OHSA 29 CFR 1910.269 Revised in 2014 Covers the operation and maintenance of electric power generation, control, transformation, transmission, and distribution lines and equipment. Covers employer required training of utility wo
Slide 11: NESC: National Electrical Safety Code
Electric Utility PPE Considerations Overview – Industry Standards NESC: National Electrical Safety Code® Section 1 – 010. Purpose: …practical safeguarding of persons, utility facilities, and affected property during the installation, operation, and maintenance of electric supply and communication fa
Slide 12: NESC and NFPA 70E Scope
Electric Utility PPE Considerations Overview – Industry Standards NESC: National Electrical Safety Code® Utility Worker Side of the Meter Line Side Electric Supply Premises Wiring Load Side Industrial Electrician Side of the Meter NFPA 70E: Standard For Electrical Safety In the Workplace 12 Copyrigh
Slide 13: ASTM F1506 Performance Specification
Electric Utility PPE Considerations Overview – Industry Standards ASTM F1506 Standard Performance Specification for Flame Resistant Textile Materials for Wearing Apparel for Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards Provides Min Requirements for FR Arc
Slide 14: ASTM F-1959 – Arc Flash Test Method
Electric Utility PPE Considerations Overview - Test Methods ASTM F-1959 – Arc Flash Test Method Determine Arc Rating (cal/cm2) of FR System The Energy Level predicting a 2nd Degree Burn Occurring. Referred to as Arc Thermal Performance Value (ATPV) or the Energy Level to Break-open The Fabric(s) (
Slide 15: ASTM F-1959 – Interpretation of Results
Electric Utility PPE Considerations Overview - Test Methods ASTM F-1959 – Interpretation of Results Arc Thermal Performance Value (ATPV): incident energy with a 50% probability of sufficient heat transfer through the fabric to predict onset of a second-degree burn* Energy Breakopen Threshold (EBT):
Slide 16: Electric Utility PPE Considerations
Electric Utility PPE Considerations 16 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 17: Success Breeds Complacency
Electric Utility PPE Considerations Wearer Protection – Arc Flash Complacent: …without awareness of some potential danger or defect. Personal Risk Assessment Human nature to assess risk based upon personal experiences Each time you take a risk and do not suffer a Experiences can provide great le
Slide 18: Safety & Health Program: PPE Last Line of Defense
Electric Utility PPE Considerations Wearer Protection – Arc Flash Safety & Health Program PPE - Last Line of Defense 4. PPE Clothing 3. Work Practices Proper Tools Eye Protection Proper Procedures Foot Protection Head Protection Hand Protection 2. Engineering Hearing Protection Technical solutions R
Slide 19: Flame Resistant and Arc Rated PPE
Electric Utility PPE Considerations Wearer Protection – Arc Flash Flame Resistant and Arc Rated PPE Does Not Ignite & Burn Does Not Melt & Drip Maintains A Barrier Insulates Wearer from Heat Resists Breaking Open Reduces Burn Injury & Increases Chances of Survival Burn Injuries Can Still O
Slide 20: Non-FR Fabrics Can Ignite and Burn
Electric Utility PPE Considerations Wearer Protection – Arc Flash Non-FR Fabrics Can Ignite and Burn and Melt When Exposed to An Electric Arc Non-FR Cotton Non-FR Cotton Before Electric Arc Flash During Electric Arc Flash After Electric Arc Flash The Untreated Cotton Garment Did Ignite and Continued
Slide 21: Arc Rated Garments Resist Ignition
Electric Utility PPE Considerations Wearer Protection – Arc Flash Arc Rated Garments Will Resist Ignition and Offer Increased Protection Arc Rated PPE Arc Rated PPE Before Electric Arc Flash During Electric Arc Flash After Electric Arc Flash Arc Rated Garment Did Not Ignite nor Break-Open 21 Copyrig
Slide 22: PPE Should be Arc Rated, Not Just FR
Electric Utility PPE Considerations Wearer Protection – Arc Flash Arc rated PPE is designed to reduce potential burn injury as a result of exposure to a arc flash event. NESC – 2012, 410.A.3: potential exposures greater than 2 cal/cm2 requires arc rated clothing not less than anticipated arc energy.
Slide 23: OSHA Accident Report Investigation Detail
Electric Utility PPE Considerations Wearer Protection – Arc Flash OSHA Accident Report Investigation Detail Accident: 200535078 - Three Employees Were Burned In Flash Arc Fire Report ID: 0751910 -- Event Date: 06/06/2012 Inspection: 316574011 At approximately 9:00 a.m. on June 6, 2012, Employee #1
Slide 24: A Single Burn Injury Can Cost Millions
Electric Utility PPE Considerations Wearer Protection – Arc Flash A Single Burn Injury Can Cost Millions Burn injuries of 40% - 60% body burn* Average hospital stay duration 54 Days (survivor) 21 days (fatality) Average cost of hospital stay → $780,000 (survivor) Additional Costs: lawsuits, prod
Slide 25: Predicted % Survivability
Electric Utility PPE Considerations Wearer Protection – Arc Flash 25% Body Burn 50% Body Burn 75% Body Burn 120 100 Chances of surviving a fire decrease… Predicted % Survivability 80 • Burn Injury 60 • Age 40 20 0 20-29 30-39 40-49 50-59 Age Bracket Source: American Burn Association 2011 study 25 Co
Slide 26: Hospital Costs by % Body Burn
Electric Utility PPE Considerations Wearer Protection – Arc Flash Hospital Costs – Depending on the % total body burn, hospital costs can be upwards of $1MM. On Average: 1 day spent in the hospital for every 1% body burn Source: 2014 National Burn Registry Annual Report 26 Copyright© 2016 DuPont. “
Slide 27: Hospital Costs – Even Fatal Burn Injuries
Electric Utility PPE Considerations Wearer Protection – Arc Flash Hospital Costs – Even fatal burn injuries can carry high hospitalization costs. Source: 2014 National Burn Registry Annual Report 27 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for a
Slide 28: Electric Utility PPE Considerations
Electric Utility PPE Considerations 28 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 29: 3 Pillars of Comfort
Electric Utility PPE Considerations PPE Considerations 3 Pillars of Comfort Thermal Comfort Garment Fit Fabric Hand Moisture Design Management Balance of Properties 29 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the ex
Slide 30: Thermal Comfort & Moisture Management
Electric Utility PPE Considerations PPE Considerations Thermal Comfort & Moisture Management How to Measure? Light Weight Fabric weight has significant impact on thermal Fabric Weight comfort and heat stress (Actual) Breathability Air flow improves evaporative and convective cooling Lower likelihood
Slide 31: The Key: All Factors Must Be In Balance
Electric Utility PPE Considerations PPE Considerations Tactile (Touch / Feel) How to Measure? Material “Hand” / Feel Human Wear Trials How a Fabric/Garment Feels to the human touch (sensory perception) Expert Panel Study Garment Fit Impacts the wearer’s perception of comfort Laundry Shrinkage Data c
Slide 32: Launderability
Electric Utility PPE Considerations PPE Considerations Ease of Care and Durability Launderability Ease of Laundering Soil Release Properties Contaminate Removal vs. Redistribution Special laundering Procedures Bleach Hard Water Others Effect of Laundering on Garment Properties Wear Durab
Slide 33: Value
Electric Utility PPE Considerations PPE Considerations Value: …the material or monetary worth of something…the worth of something compared to the price paid or asked for it. Conditioned to Look at Initial Procurement Cost Pressure to save money on the front end Quality decision for short term gains
Slide 34: Cost Effectiveness by Garment Life Cycle
Electric Utility PPE Considerations PPE Considerations Cost Effectiveness can be gauged by Garment Life Cycle Attribute Measurements Field Trials and Actual Use Fabric/Garment Testing Key Considerations Durability FR Protection Durability Fabric and Garment Wear Durability Repair/Replace
Slide 35: Electric Utility PPE Considerations
Electric Utility PPE Considerations 35 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 36: Fabric Comparison: Nomex MHP vs FR Treated Cotton
Electric Utility PPE Considerations Fabric Comparison DuPont Nomex® MHP 7.0oz FR Treated Cotton 88/12 7.0 oz Actual Weight 7.0 oz/sqyd Typical Actual Weight 8.0 oz/sqyd Multiple Hazard Protection Multiple Hazard Protection ATPV 8.4 ATPV 8.7 Inherent Nomex® and Kevlar® Based engineered
Slide 37: IFTH Comfort Study Results
Electric Utility PPE Considerations Fabric Comparison IFTH Comfort Study Results French Institute Textile and Apparel Best Scores For Softness: Pleasant sensation to the touch Smooth: Low perception of harshness Thinnest: Low height of the samples perceived between fingers Most drape: Evalua
Slide 38: Designed for Optimal Moisture Management
Electric Utility PPE Considerations Fabric Comparison Designed for Optimal Moisture Management Moisture Regain % Measures how much moisture is absorbed than by a fabric from its surroundings 36% FRTC Drier 88/12 Fabrics which absorb moisture easier can be prone to slowly releasing (more water to dry
Slide 39: Break Strength + Abrasion Resistance = Durability
Electric Utility PPE Considerations Fabric Comparison Break strength + Abrasion Resistance = Predicted Durability 60% compared to Higher break FRTC 88/12 strength after laundering 100X IL 200X IL Nomex® MHP can provide better durability Strength, High Aramid %= Durability, Appearance Content 100X IL
Slide 40: Superior Fit Retention and Professional Appearance
Electric Utility PPE Considerations Fabric Comparison Superior Fit Retention and Professional Appearance Low Shrinkage = Better Fit Retention Color Fastness = Appearance Retention 50+% 37% 20% 160% 48% less color loss less color loss less shrinkage less shrinkage less shrinkage 25 washes 200 washes
Slide 41: Saves Money Over Time
Electric Utility PPE Considerations Fabric Comparison DuPont Nomex® MHP Can Provide a Lower Life Cycle Cost Low shrinkage Better durability Saves Money Over Time Excellent appearance retention $17,500 * Replacement Costs Can Be Significant FRTC Nomex® 88/12 MHP *Assumptions: 200 wearer program
Slide 42: Electric Utility PPE Considerations
Electric Utility PPE Considerations 42 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 43: Conclusions and Summary
Electric Utility PPE Considerations Conclusions and Summary Arc flash exposure can cause serious injury and death A single burn injury can costs millions and impose human suffering Proper PPE matching the assessed hazard is essential to worker safety Choose Fabric First - Fabric properties dictate d
Slide 44: For additional questions
For additional questions – please feel free to reach out to Dennis directly at: [email protected] In addition – you can ask our team questions live at the upcoming NSC show – booth # 1439 44 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for a
Slide 45: Electric Utility PPE Considerations
Electric Utility PPE Considerations 45 Copyright© 2016 DuPont. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”
Slide 46: Disclaimer
Electric Utility PPE Considerations Disclaimer “This information corresponds to our current knowledge on the subject and may be subject to revision as new knowledge becomes available. It is your responsibility to investigate other sources of information on this issue that more appropriately addres