HeartWare International Inc

HeartWare International — Wells Fargo Securities 2011 Healthcare Conference

33 slides from HeartWare International's conference presentation, Jun 22, 2011

  1. Slide 1: Wells Fargo Securities 2011 Healthcare Conference

    Slide 1: Wells Fargo Securities 2011 Healthcare Conference

    Wells Fargo Securities2011 Healthcare ConferenceDoug GodshallChief Executive Officer and PresidentJune 22, 2011

  2. Slide 2: Safe Harbor Statement

    Slide 2: Safe Harbor Statement

    Safe Harbor Statement Forward-Looking Statements This presentation contains forward-looking statements that are based on our management's beliefs, assumptions and expectations and on information currently available to our management. Generally, you can identify forward-looking statements by terms su

  3. Slide 3: Heart Failure: A degenerative and terminal disease

    Slide 3: Heart Failure: A degenerative and terminal disease

    Heart Failure A degenerative and terminal diseaseAffects over 20 million people globally (5+ million in the US)1 million new cases diagnosed every year300,000 deaths per year in the US (1 in 8 deaths)At least 1 million patients in NYHA Class IV, the end-stage of the diseaseIn the US, heart failure r

  4. Slide 4: Heart Failure: The Final Cardiovascular Disease

    Slide 4: Heart Failure: The Final Cardiovascular Disease

    1st Qtr 2nd Qtr 1980 401 350 423 345 439 330 464 310 531 305 557 300 582 295 605 290 634 285 643 270 1990 701 265 764 255 822 250 875 240 874 235 872 235 870 220 957 210 978 205 962 200 2000 999 189 995 178 970 171 2003 1037 Coronary Deaths Coronary deaths are down by half But heart failure has almo

  5. Slide 5: Global VAD Market Acceleration Continues

    Slide 5: Global VAD Market Acceleration Continues

    Global VAD Market Acceleration Continues * Industry reports, HeartWare estimates, Thoratec estimates CAUTION: Investigational device. Limited by United States law to investigational use.

  6. Slide 6: HeartWare Ventricular Assist System

    Slide 6: HeartWare Ventricular Assist System

    HeartWare(r) Ventricular Assist System HVAD(r) miniaturized implantable blood pump Pericardial placement - no pump pocketProvides up to 10 L/min of flowCentrifugal design, continuous flowHybrid magnetic / hydrodynamic impeller suspensionOptimizes flow, pump surface washing, and hemocompatibilityThin

  7. Slide 7: Design Enables Pericardial Placement

    Slide 7: Design Enables Pericardial Placement

    Design Enables Pericardial Placement Design benefitsEfficient powerWide blade impeller enables low fluid stressUser friendly tools may decrease surgery time Pericardial benefitsNo abdominal surgeryNo pump pocketPotential to expand pool of treatable patients Fundamental attributes resonating globally

  8. Slide 8: Simple, Elegant Fluid Dynamics

    Slide 8: Simple, Elegant Fluid Dynamics

    Simple, Elegant Fluid Dynamics Secondary flow path Washes underside and center post regions Tertiary flow pathProvides fluid "cushion"; washes thrust bearings Primary flow pathWashes flow channels and immediately enters outflow graft Levitated impeller; Free from mechanical contact points CAUTION: I

  9. Slide 9: Leading a Small Revolution

    Slide 9: Leading a Small Revolution

    Leading a Small Revolution More than 1,000 HeartWare Ventricular Assist System Implants GloballyHeartWare has grown to 260+ employees todayHeadquarters near Boston, Massachusetts (Framingham)Manufacturing in Miami, Florida Development and operations facility in Kirrawee, NSW CAUTION: Investigational

  10. Slide 10: HeartWare: Strengthened Base for Future Growth

    Slide 10: HeartWare: Strengthened Base for Future Growth

    HeartWare: Strengthened Base for Future Growth Maturing commercial organization in EuropeBolstered manufacturing to accommodate clinical ramp in USAugmented field team to educate and service larger commercial and clinical customer basePositioning organization for FDA audit process and US launch prep

  11. Slide 11: Geographic revenue breakdown

    Slide 11: Geographic revenue breakdown

    Geographic revenue breakdown Geographic revenue breakdown

  12. Slide 12: International Rollout Gaining Momentum

    Slide 12: International Rollout Gaining Momentum

    International Rollout Gaining Momentum CAUTION: Investigational device. Limited by United States law to investigational use. International market growth robustExpanding global acceptance56 customers, 18 countriesReported 134 units sold in Q1Follows 112 in Q3; 161 in Q4Expanded capabilities to capita

  13. Slide 13: Clinical and regulatory tracking - HVAD

    Slide 13: Clinical and regulatory tracking - HVAD

    Clinical and regulatory tracking - HVAD United States - Bridge-to-Transplant United States - Continued Access for BTTUnited States - Destination Therapy DT IDE Approved by FDA June 2010 First implants Aug 2010 Began April 2010; Two 54-patient allotments complete; Third enrolling CAUTION: Investigati

  14. Slide 14: Two Largest VAD Trials

    Slide 14: Two Largest VAD Trials

    Two Largest VAD Trials ADVANCEBridge-to-Transplant140 patients at 30 sites6-month follow up completed 8/2010Control: contemporaneous patients in INTERMACS registryPMA submitted 12/27/10Met primary endpointContinued Access Protocol in place29 of 30 sites initiated in CAP94 ENDURANCEDestination Therap

  15. Slide 15: ADVANCE BTT Trial: Summary of Results

    Slide 15: ADVANCE BTT Trial: Summary of Results

    94% survival at 180 days, 91% projected survival at 360 daysHVAD pump demonstrated non-inferiority to contemporaneously implanted, commercially available ventricular assist devicesImplantation of the HVAD pump was associated with a 92% probability of success at 180 daysAdverse event profile in line

  16. Slide 16: ADVANCE Trial Treatment Group Outcomes

    Slide 16: ADVANCE Trial Treatment Group Outcomes

    Days Post Implant Proportion of Patients 62.8% Alive 29.2% Transplant 3.6% Death 4.4% Device Exchange 92.0% Transplant or Alive ADVANCE Trial Treatment Group Outcomes (Per Protocol Population) Patients at Risk 137 125 104 86 58 31 22 NOTE: Original device in place for all outcomes CAUTION: Investiga

  17. Slide 17: Applying Seattle Heart Failure Model to ADVANCE

    Slide 17: Applying Seattle Heart Failure Model to ADVANCE

    Applying Seattle Heart Failure Model to ADVANCE Figure 1: SHFM Estimated Survival Wayne C. Levy, et al, ISHLT 2011

  18. Slide 18: Overall Survival Comparison: SHFM vs. ADVANCE

    Slide 18: Overall Survival Comparison: SHFM vs. ADVANCE

    Overall Survival Comparison: SHFM vs. ADVANCE Figure 1: SHFM Estimated Survival Figure 1: SHFM Estimated Survival Wayne C. Levy, et al, ISHLT 2011

  19. Slide 19: ADVANCE and CAP Update June 21, 2011

    Slide 19: ADVANCE and CAP Update June 21, 2011

    ADVANCE and CAP Update June 21, 2011

  20. Slide 20: Current Status of ADVANCE and CAP

    Slide 20: Current Status of ADVANCE and CAP

    ADVANCE:140 patients enrolled - last implant Feb 28, 201052 patients remain on pump (37%) CAP:144 patients enrolled111 remain on pump (77%)BTT / CAP combined: 284 enrolled in both trials for 217 patient-years of support Current Status of ADVANCE and CAP

  21. Slide 21: Methodology and Objective

    Slide 21: Methodology and Objective

    Methodology and Objective Event rates for device exchange for thrombus post discharge, GI bleeding and strokes were compared by time on pump for the following periods:ADVANCE and CAP combined to June 14, 2011 (i.e. the current overall rates): 284 patients for 217 patient-yearsADVANCE and CAP from Ma

  22. Slide 22: Distribution of Time on Pump

    Slide 22: Distribution of Time on Pump

    Distribution of Time on Pump Total = 163 patients on HVAD support during the period March 14 - June 14 Majority of patients confirmed to be on 325 mg (CHART) CAUTION: Investigational device. Limited by United States law to investigational use.

  23. Slide 23: Exchange Rates for Suspected Thrombus

    Slide 23: Exchange Rates for Suspected Thrombus

    (CHART) Exchange Rates for Suspected Thrombus One exchange for thrombus in 163 patients March 14 - June 14 Resembles ISHLT finding of 1 exchange in 73 patient years with 325 mg ASA 217 patient years in BTT/CAP and 40 from March 14 - June 14 CAUTION: Investigational device. Limited by United States l

  24. Slide 24: GI Bleeding

    Slide 24: GI Bleeding

    GI Bleeding (CHART) CAUTION: Investigational device. Limited by United States law to investigational use.

  25. Slide 25: Stroke Rates Total Trial vs. Recent Quarter

    Slide 25: Stroke Rates Total Trial vs. Recent Quarter

    Stroke Rates Total Trial vs. Recent Quarter Stroke Rates Total Trial vs. Recent Quarter CAUTION: Investigational device. Limited by United States law to investigational use.

  26. Slide 26: Investigator Update Summary

    Slide 26: Investigator Update Summary

    284 patients have been enrolled in ADVANCE and CAP for more than 217 patient-years of supportSurvival has been consistently high in all trials to dateSepsis and driveline infections are notably infrequentGI bleeding rate and bleeding in general remain low Full dose aspirin (325 mg) appears to be an

  27. Slide 27: Development Priorities for 2011

    Slide 27: Development Priorities for 2011

    Development Priorities for 2011 "Evergreen" HVADEnhancements to pump and algorithmsIntroduce new tools to improve implantUpgrade patient accessoriesDrive MVAD to First-in-ManMultiple versions under wayDesign for AE reduction to expand treatable populationAccelerate NG ElectronicsNext Generation Cont

  28. Slide 28: Evergreen HVAD - Enhancements for Next Months

    Slide 28: Evergreen HVAD - Enhancements for Next Months

    Evergreen HVAD - Enhancements for Next 12 Months Improved patient packs Redesigned product packaging New Apical Coring Tool Sintered inflow cannula Revised controller with updated software Shower bag CAUTION: Investigational device. Limited by United States law to investigational use.

  29. Slide 29: Sintered Inflow

    Slide 29: Sintered Inflow

    Sintered Inflow Sintered Inflow CAUTION: Investigational device. Limited by United States law to investigational use. FDA approved sintering for both BTT/CAP and DT studies in AprilFirst sintered pump implants in May34 sites have already received IRB approval for sintered pumpsBSI approved sintered

  30. Slide 30: Compelling Pipeline - Miniaturized VAD design

    Slide 30: Compelling Pipeline - Miniaturized VAD design

    Compelling Pipeline - Miniaturized VAD design Expanded portfolio of MVAD designsExploring new patient populationsMore than 75 animal studies conducted to date; strong early resultsGLP animal studies started Q1 '11First-in-man studies Q1 '12Wide blade impeller with hybrid suspension allows significan

  31. Slide 31: Selected Financial Snapshot

    Slide 31: Selected Financial Snapshot

    Selected Financial Snapshot RevenueQ1 2011 revenues $18M; up 68% from Q1 in 20102010 revenues of $55M; up 128% from $24M 2009 (CHART) $ Millions Implant rate and growth likely to be variable in 2011Capital structureTreasury exceeds $214M in capital at 3/31Convertible debt $143M ($100 conversion pric

  32. Slide 32: Another Busy Year

    Slide 32: Another Busy Year

    Another Busy Year Initiation of MVAD GLP animal studies in Q1 2011 ^Secure reimbursement and launch HVAD in FrancePreparation for PMA audit; potential advisory committee panelISHLT presentation of ADVANCE trial and CAP data ^Drive enrollment in DT and CAPPublication of ADVANCE dataEnroll 300th patie

  33. Slide 33: Leading a Small Revolution

    Slide 33: Leading a Small Revolution

    Leading a Small Revolution CAUTION: Investigational device. Limited by United States law to investigational use.

Source: SEC EDGAR · 8-K filed Jun 22, 2011

More decks from HeartWare International Inc