DuPont de Nemours, Inc. · NYSE:DD

DuPont de Nemours — DuPont — 2008 Annual Meeting of the NPRA

26 slides from DuPont de Nemours's conference presentation, Mar 10, 2008

  1. Slide 1: Mild Hydrocracking using IsoTherming Technology

    Mild Hydrocracking using IsoTherming™ Technology presented by Carmo J. Pereira DuPont Engineering Technology at the 2008 Annual Meeting of the NPRA San Diego, California March 10, 2008 DuPont™ IsoTherming™

  2. Slide 2: Introduction

    MHC using IsoTherming™ Technology (continued) Introduction Petroleum refiners are continuing to install hydroprocessing capacity in response to market needs. Regulations associated with lowering sulfur levels in fuels are driving increased desulfurization. There is an increased need to upgrade less

  3. Slide 3: IsoTherming Process Technology

    MHC using IsoTherming™ Technology (continued) IsoTherming™ technology builds on decades of commercial hydrotreating experience. Conventional catalysts may be used. The technology is applicable for a broad range of hydroprocessing applications that include sulfur reduction and upgrading. The scientif

  4. Slide 4: Diesel IsoTherming reactor revamp

    MHC using IsoTherming™ Technology (continued) hydrogen demand environment greatly improving its performance. IsoTherming™ reactor design is based on the sulfur target levels after the conventional reactor. H 2 Make-up Compressor H2 Make-up Recycle Compressor IsoTherming® Tricle-Bed Reactor Reactor H

  5. Slide 5: Benefits of MHC in FCC feed pretreatment

    MHC using IsoTherming™ Technology (continued) IsoTherming™ Process Technology for Mild Hydrocracking (MHC) The benefits of hydrotreating Fluid Catalytic Cracking (FCC) unit feed are well known in the industry. Figure 3 illustrates a role for MHC in FCC feed pretreatment [2]. MHC reduces feed nitroge

  6. Slide 6: Design feed properties and product specifications

    MHC using IsoTherming™ Technology (continued) Table 2. Design Feed Properties. Feed Case A Case B Case C Components VGO, DAO VGO, HCGO VGO, HCGO, CGO Feed Rate, BPSD 15,000 55,000 32,500 Gravity, API° 17.4 18.5 22.3 S, ppm 28,000 26,700 25,600 N, ppm 1,750 1,580 1,300 Con Carbon, wt% 1.81 0.71 0.25

  7. Slide 7: Mild Hydrocracking Economic Estimates

    MHC using IsoTherming™ Technology (continued) Mild Hydrocracking (MHC) Economic Estimates Pro forma economic estimates have been completed for a case of MHC using IsoTherming™ technology. In contrast to conventional technology, the IsoTherming process has a hot low pressure separator and a liquid re

  8. Slide 8: Mild Hydrocracking using IsoTherming Technology

    Mild Hydrocracking using IsoTherming™ Technology Carmo J. Pereira, Ph.D. Scott L. Webster DuPont Engineering Technology Glenn C. Liolios DuPontTM IsoTherming™ Clean Fuel Technologies Luis E. Murillo, Ph.D. Wayne B. Ely Michael D. Ackerson, Ph.D. Michael J. Hennessy, Ph.D. M. Steven Byars, Ph.D. DuPo

  9. Slide 9: IsoTherming

    2 IsoTherming™ • Developed by Process Dynamics, Inc. • First commercial unit: ULSD unit revamp in April 2003 • Licensed by DuPontTM IsoTherming™ Clean Fuel Technologies • Eight licenses • 2 ULSD grassroots • 3 ULSD revamps • 3 Mild Hydrocrackers DuPont™ IsoTherming™

  10. Slide 10: IsoTherming Applications

    3 IsoTherming™ Applications • ULSD – Lowest cost revamp in comparison with conventional trickle-bed technology • Severe gas oil hydrotreating • Mild hydrocracking • Lube and wax DuPont™ IsoTherming™

  11. Slide 11: IsoTherming Technology

    4 IsoTherming™ Technology • Liquid phase reactor • Hydrogen is dissolved in liquid phase. • Conventional catalyst technology • Catalyst selection is based on refiner need. Additional catalyst development is underway. • Broad range of application • Lower sulfur levels • Upgrading • Revamp and grass r

  12. Slide 12: IsoTherming Reactor Technology

    5 IsoTherming™ Reactor Technology • Hydrogen is provided in large excess by recycling product liquid. • Underlying chemistry is the same as for conventional hydroprocessing. • Flow distribution is not an important issue. • Catalyst is completely wet. • Hydrogen is available at the active site. • Adi

  13. Slide 13: Conventional Unit Revamp

    6 Conventional Unit Revamp New Makeup Hydrogen Compressor Makeup Hydrogen Fuel Gas Makeup Hydrogen Compressor OH Separator Purge Gas Wild Naphtha OH Condenser Recyle Compressor Product Diesel Amine Treating Fired Heater Feed/Effluent HX Feed/Stripper Water Btms HX Feed HHPS Overhead HHPS/CHPS Cooler

  14. Slide 14: IsoTherming Unit Revamp

    7 IsoTherming™ Unit Revamp H2 Make-up Compressor H2 Make-up Recycle Compressor IsoTherming™ Trickle-Bed Reactor Reactor Heater To amine contactor Feed Heater Purge Feed Sour naphtha to crude Stripper Feed Pump Recycle Pump Sour water Stripping steam HHPS To sour water Water Product to storage DuPont

  15. Slide 15: Improvements in FCC yields from MHC

    8 Improvements in FCC yields from MHC Fuel Gas Naphtha Mild VGO Hydrocracking Diesel S=1.5% S=100-200 ppm Gasoline S<10 ppm FCC LCO S~0.07% Slurry S~0.29% Axens (2008) DuPont™ IsoTherming™

  16. Slide 16: Mild Hydrocracking Benefits

    9 Mild Hydrocracking Benefits • Avoid post treating FCC gasoline • 1,200 ppm sulfur feed yields 60 ppm gasoline • minimize octane losses • Improved FCC yields • 5 percent increased yield every 1,000 ppm nitrogen removed • Reduced stack emissions • Possible debottleneck • Improved FCC catalyst life D

  17. Slide 17: FCC Yield vs Feed Nitrogen

    10 FCC Yield 80 70 LPG + Gasoline 60 Yield, vol % 50 40 30 20 LCO 10 0 0 500 1000 1500 2000 2500 3000 FCC Feed N, ppm DuPont™ IsoTherming™

  18. Slide 18: Mild Hydrocracker Case Study: Design Feed Properties

    11 Mild Hydrocracker Case Study Design Feed Properties Feed Case A Case B Case C Components VGO, DAO VGO, HCGO VGO, HCGO, CGO Feed Rate, BPSD 15,000 55,000 32,500 Gravity, API° 17.4 18.5 22.3 S, ppm 28,000 26,700 25,600 N, ppm 1,750 1,580 1,300 Con Carbon, wt% 1.81 0.71 0.25 D-2887 IBP 425 447 416 5

  19. Slide 19: Mild Hydrocracker Case Study: Design Products

    12 Mild Hydrocracker Case Study Design Products Case A Case B Case C Feed VGO, DAO VGO, HCGO VGO, HCGO, CGO Light naphtha, S < 20 ppm Naphtha, S < 10 ppm No sulfur spec. < 5 ppm Kerosene, S < 8 ppm No sulfur spec. < 8 ppm No sulfur Diesel, S No sulfur spec. < 8 ppm spec. FCC Feed, S < 700 ppm < 800

  20. Slide 20: Catalyst/Reactor Options

    13 Catalyst/Reactor Options VGO/DAO VGO H2 H2 S=15,000 ppm S=15,000 ppm N=2,500 ppm N=1,500 ppm Demet Demet Resid HDS/HDN HDS/HDN S=1,000 ppm S=400 ppm N=100 ppm N=20 ppm MHC/ HDS/HDN HC MHC/ HC N low enough for mild hydrocracking catalyst (MHC) or crystalline hydrocracking (HC) catalyst DuPont™ Iso

  21. Slide 21: Unit Design

    14 Unit Design M-01 M-02 E- 06 RX-01 RX-02 TO FG GO FEED TREATING V-01 F-01 CWR HX-01 RX-01 V-04 E-03 CWR CWR E-01 E-02 E- 05 E- 04 P-01 CWS RX-03 99.0% H2 MAKEUP LC HYDROGEN CWS CWS 3rd stage 2nd stage 1st stage P-02 P-03 C-01 LC LC PRODUCT TO FCC E-15 E-16 150 BFW E-07 PSIG E-10 STEAM V-02 TO FG T

  22. Slide 22: Major Equipment Differences

    15 Major Equipment Differences IsoTherming™ Conventional Hot High Pressure Separator No Yes Cold High Pressure Separator No Yes Recycle Gas Compressor No Yes High Pressure Off Gas Cooler No Yes Hot Low Pressure Separator Yes No High Pressure Amine Contactor No Yes Stripper Preheat Exchangers No Yes

  23. Slide 23: Cost Comparison Estimate

    16 Cost Comparison Estimate(a) 30,000 bbl/day Mild Hydrocracker 2,000 psi Operating Pressure IsoTherming™ Conventional Capital: $67.3 MM $135.0 MM Utility: Fuel Gas, MM Btu/hr 22.6 23.9 Power, KWH 4360 6520 Steam gen, lb/hr 59,000 46,700 (a) Source: Process Dynamics DuPont™ IsoTherming™

  24. Slide 24: Experience List

    17 Experience List • East Coast US 46,000 BPD ULSD – Revamp - Basic Design (2Q) • El Dorado, KS 55,000 BPD Mild Hydrocracker – Detailed Eng. • Artesia, NM 30,000 BPD Mild Hydrocracker – Detailed Eng. • Salt Lake City, UT 15,000 BPD Mild Hydrocracker – Detailed Eng. • Yorktown, VA 12,000 BPD ULSD Gra

  25. Slide 25: Summary

    18 Summary • Mild hydrocracking may be effectively used for upgrading, e.g., pre-treating FCC feed. • IsoTherming™ technology may be designed or retrofitted for ULSD and mild hydrocracking service. • The technology allows the refiner to simultaneously meet conversion, fuel sulfur and fuel nitrogen s

  26. Slide 26: DuPont IsoTherming

    The miracles of science DuPont™ IsoTherming™

DuPont — 2008 Annual Meeting of the NPRA on 6ix